Service time: Monday to Friday 9:00-18:00
VAL-US-277/40/4+0-FM - VAL-US-277/40/4+0-FM 2910375 PHOENIX CONTACT Type 2 surge protection device
In Stock Hot Product

VAL-US-277/40/4+0-FM

VAL-US-277/40/4+0-FM 2910375 PHOENIX CONTACT Type 2 surge protection device

$0.00USD
3154 in stock
Key Specifications
GTIN:4055626445144
Note:Made to Order (non-returnable)
Orderkey:2910375
(General):530 V AC (120 min / safe failure mode)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626445144
NoteMade to Order (non-returnable)
Orderkey2910375
(General)530 V AC (120 min / safe failure mode)
Packing unit1 pc
Country of originUS (United States)
(Connection data)N-G
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)1 A DC
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
SPD Type (Connection data)1
Depth (Key Commercial Data)65.5 mm
Width (Key Commercial Data)71.2 mm
EN type (Ambient conditions)T2
Height (Key Commercial Data)98.7 mm
Nominal voltage UN (General)277/480 V AC (TN-S)
(Indicator/remote signaling)4.5 Nm (25 mm² ... 35 mm²)
Nom. voltage (Connection data)277/480 V AC
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 450 µA
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
TOV behavior at UT(L-N) (General)480 V AC (5 s / withstand mode)
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)L-L
Weight per Piece (excluding packing)426.000 g
Housing material (Ambient conditions)PA 6.6
Operating current (UL specifications)1 A AC
Operating voltage (UL specifications)125 V AC
Residual voltage Ures(L-PE) (General)≤ 2 kV (at In)
Residual voltage Ures(N-PE) (General)≤ 2 kV (at In)
Stripping length (Protective circuit)7 mm
Tightening torque (UL specifications)2 lbf-in. ... 4 lbf-in.
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)4 Div.
Operating current (Protective circuit)5 mA AC ... 750 mA AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Tightening torque (Protective circuit)0.25 Nm
Mode of protection (Ambient conditions)L-N
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)4
Screw thread (Indicator/remote signaling)M5
Standards/regulations (UL connection data)IEC 61643-11 2011
Voltage protection level Up(L-N) (General)≤ 4 kV
Power distribution system (Connection data)Wye
Voltage protection level Up(L-PE) (General)≤ 2 kV
Voltage protection level Up(N-PE) (General)≤ 2 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-S
IEC test classification (Ambient conditions)II
Short-circuit current rating ISCCR (General)25 kA
Max. backup fuse with branch wiring (General)125 A (gG)
Maximum continuous voltage UC(N-PE) (General)385 V AC
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Nominal discharge current In (Connection data)20 kA
Tightening torque (Indicator/remote signaling)3 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (UL specifications)30 ... 14
Conductor cross section AWG (Protective circuit)28 ... 16
Nominal discharge current In(8/20) µs (General)20 kA
Maximum Surge Current per Phase (Connection data)40 kA
Tightening torque (UL indicator/remote signaling)30 lbf-in.
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General)40 kA
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Short-circuit current rating (SCCR) (Connection data)200 kA
Voltage protection rating VPR (L-G) (Connection data)2000 V
Voltage protection rating VPR (L-L) (Connection data)2500 V
Voltage protection rating VPR (L-N) (Connection data)1500 V
Voltage protection rating VPR (N-G) (Connection data)1500 V
Maximum continuous operating voltage UC(L-PE) (General)385 V AC
Conductor cross section AWG (Indicator/remote signaling)15 ... 2
Conductor cross section solid (Indicator/remote signaling)1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling)10 ... 2
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 16 mm²
Maximum continuous operating voltage MCOV (L-G) (Connection data)385 V AC
Maximum continuous operating voltage MCOV (L-L) (Connection data)750 V AC
Maximum continuous operating voltage MCOV (L-N) (Connection data)750 V AC
Maximum continuous operating voltage MCOV (N-G) (Connection data)385 V AC

Product Description

4-channel surge protection device with remote indication contact, for 277/480 V AC, 4 wires plus ground.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top