Key Specifications
:T2
Note:2011
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
T2
Note2011
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth65.7 mm (incl. DIN rail 7.5 mm)
Width35.6 mm
Height96.8 mm
EN typeT2
UL typetype 1
Altitude≤ 2000 m (amsl)
SPD Type1
Product typeSurge protection for NEMA power supply units
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Product familyVALVETRAB US
Connection nameRemote fault indicator contact
Nominal voltage277 V AC
Article revision04
Horizontal pitch2 Div.
Housing materialPA 6.6
Pollution degree2
Stripping length16 mm
Connection methodScrew connection
Nominal frequency50/60 Hz
Operating current5 mA AC ... 750 mA AC
Operating voltage5 V AC ... 250 V AC
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (1.5 mm² ... 16 mm²)
Mode of protectionL-N
Nominal voltage UN277 V AC (TN-S)
Switching functionChangeover contact
Dimensional drawing
Direction of action1L-N & N-GND
Insulating materialPA 6.6/PBT
Number of positions2
AC operating current1 A AC
Degree of protectionIP20 (only when all terminal points are used)
Follow current (L-G)100 A
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 5 µA
CTI value of material600
Standards/regulationsEN 60664-1 / EN 61643-11
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN-S
IEC test classificationII
TOV behavior at UT(L-N)480 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Power distribution systemSingle phase
Residual voltage Ures(L-N)≤ 1.8 kV (at In)
Conductor cross section AWG15 ... 2
Residual voltage Ures(L-PE)≤ 2.2 kV (at In)
Residual voltage Ures(N-PE)≤ 0.4 kV (at In)
Nominal discharge current In20 kA
Conductor cross section rigid1.5 mm² ... 35 mm²
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 80 °C
Maximum Surge Current per Phase40 kA
Conductor cross section flexible1.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Voltage protection level Up(L-N)≤ 1.8 kV
Voltage protection level Up(L-PE)≤ 2.2 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring125 A (gG)
Short-circuit current rating (SCCR)200 kA
Voltage protection rating VPR (L-G)2000 V
Voltage protection rating VPR (L-N)1500 V
Voltage protection rating VPR (N-G)1200 V
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs20 kA
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs40 kA
Follow current interrupt rating Ifi(N-PE)100 A (305 V AC)
Maximum continuous operating voltage UC(L-N)385 V AC
Maximum continuous operating voltage UC(N-PE)305 V AC
Maximum continuous operating voltage MCOV (L-G)385 V AC
Maximum continuous operating voltage MCOV (L-N)385 V AC
Maximum continuous operating voltage MCOV (N-G)305 V AC

Product Description

2-channel surge protection device with remote indication contact, for 277 V AC, 2 wires plus ground.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty