Service time: Monday to Friday 9:00-18:00
VAL-US-120/65/2+0-FM - VAL-US-120/65/2+0-FM 2910357 PHOENIX CONTACT Type 1/2 surge protection device
In Stock Hot Product

VAL-US-120/65/2+0-FM

VAL-US-120/65/2+0-FM 2910357 PHOENIX CONTACT Type 1/2 surge protection device

$0.00USD
4049 in stock
Key Specifications
GTIN:4055626444970
Note:Made to Order (non-returnable)
Orderkey:2910357
(General):240 V AC (120 min / safe failure mode)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626444970
NoteMade to Order (non-returnable)
Orderkey2910357
(General)240 V AC (120 min / safe failure mode)
Packing unit1 pc
Country of originUS (United States)
(Connection data)L-G
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)1 A DC
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 25 ns
SPD Type (Connection data)1
Depth (Key Commercial Data)77.5 mm
Width (Key Commercial Data)35.6 mm
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)96.8 mm
Nominal voltage UN (General)120/240 V AC (TN-C)
TOV behavior at UT (General)208 V AC (5 s / withstand mode)
(Indicator/remote signaling)4.5 Nm (25 mm² ... 35 mm²)
Nom. voltage (Connection data)120/240 V AC (Split phase)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 0.8 mA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 0.8 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)L-L
Weight per Piece (excluding packing)281.000 g
Housing material (Ambient conditions)PA 6.6
Operating current (UL specifications)1 A AC
Operating voltage (UL specifications)125 V AC
Stripping length (Protective circuit)7 mm
Tightening torque (UL specifications)2 lbf-in. ... 4 lbf-in.
Voltage protection level Up (General)≤ 0.8 kV
Connection method (Protective circuit)Screw connection
Horizontal pitch (Key Commercial Data)2 Div.
Operating current (Protective circuit)5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Tightening torque (Protective circuit)0.25 Nm
Mode of protection (Ambient conditions)L-PEN
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)2
Screw thread (Indicator/remote signaling)M5
Standards/regulations (UL connection data)IEC 61643-11 2011
Power distribution system (Connection data)Split phase
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-C
IEC test classification (Ambient conditions)I / II
Short-circuit current rating ISCCR (General)25 kA
Max. backup fuse with branch wiring (General)160 A (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Screw connection
Nominal discharge current In (Connection data)20 kA
Tightening torque (Indicator/remote signaling)4.5 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (UL specifications)30 ... 14
Conductor cross section AWG (Protective circuit)28 ... 16
Nominal discharge current In(8/20) µs (General)20 kA
Maximum Surge Current per Phase (Connection data)65 kA
Tightening torque (UL indicator/remote signaling)30 lbf-in.
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General)25 kA
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General)80 A (gG)
Short-circuit current rating (SCCR) (Connection data)200 kA
Voltage protection rating VPR (L-G) (Connection data)700 V
Voltage protection rating VPR (L-L) (Connection data)1200 V
Conductor cross section AWG (Indicator/remote signaling)15 ... 2
Maximum continuous operating voltage UC(L-PEN) (General)175 V AC
Nominal discharge current In(8/20) µs (L-PEN) (General)12.5 kA
Conductor cross section solid (Indicator/remote signaling)1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling)10 ... 2
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 25 mm²
Maximum continuous operating voltage MCOV (L-G) (Connection data)175 V AC
Maximum continuous operating voltage MCOV (L-L) (Connection data)350 V AC

Product Description

2-channel surge protection device with remote indication contact, for 120/240 V AC (split phase configuration), 3 wires.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top