Service time: Monday to Friday 9:00-18:00
VAL-SEC-T2-3S-350/40-FM - VAL-SEC-T2-3S-350/40-FM 2909635 PHOENIX CONTACT Type 2 surge arrester
In Stock Hot Product

VAL-SEC-T2-3S-350/40-FM

VAL-SEC-T2-3S-350/40-FM 2909635 PHOENIX CONTACT Type 2 surge arrester

$0.00USD
3359 in stock
Key Specifications
GTIN:4055626378206
Orderkey:2909635
(General):63 A (gG / TWIN ferrule 2x 10mm²)
Catalog page:Page 45 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626378206
Orderkey2909635
(General)63 A (gG / TWIN ferrule 2x 10mm²)
Catalog pagePage 45 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)EN 61643-11 2012
Custom tariff number85363030
(Ambient conditions)PBT-FR
(Protective circuit)1 A DC (30 V DC)
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)light grey RAL 7035
Depth (Key Commercial Data)74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)49.2 mm
EN type (Ambient conditions)T2
Height (Key Commercial Data)97.9 mm
Nominal voltage UN (General)240/415 V AC (TN-S)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 1 µA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Response time tA(L-N) (General)≤ 25 ns
Response time tA(L-PE) (General)≤ 100 ns
Response time tA(N-PE) (General)≤ 100 ns
Degree of protection (Dimensions)IP20
Screw thread (Protective circuit)M2
TOV behavior at UT(L-N) (General)415 V AC (5 s / withstand mode)
Mounting type (Ambient conditions)DIN rail: 35 mm
TOV behavior at UT(N-PE) (General)1200 V AC (200 ms / withstand mode)
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Residual voltage Ures(L-N) (General)≤ 1.5 kV (at In)
Weight per Piece (excluding packing)378.000 g
Housing material (Ambient conditions)PA 6.6-FR 20% GF
Residual voltage Ures(N-PE) (General)≤ 0.7 kV (at In)
Stripping length (Protective circuit)7 mm
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)2.7 Div.
Operating current (Protective circuit)5 mA AC ... 1 A AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Tightening torque (Protective circuit)0.25 Nm
Mode of protection (Ambient conditions)L-N
Standards/regulations (Connection data)IEC 61643-11 2011
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)4
Screw thread (Indicator/remote signaling)M5
Voltage protection level Up(L-N) (General)≤ 1.5 kV
Voltage protection level Up(L-PE) (General)≤ 1.9 kV
Voltage protection level Up(N-PE) (General)≤ 1.5 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-S
IEC test classification (Ambient conditions)II
Short-circuit current rating ISCCR (General)25 kA (in case of 315 A gG backup fuse)
Max. backup fuse with branch wiring (General)315 A (gG)
Maximum continuous voltage UC(N-PE) (General)264 V AC
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Tightening torque (Indicator/remote signaling)4.5 Nm
Conductor cross section AWG (Protective circuit)28 ... 16
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Follow current interrupt rating Ifi(N-PE) (General)100 A (264 V AC)
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General)40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)
Maximum continuous operating voltage UC(L-N) (General)350 V AC
Nominal discharge current In(8/20) µs (L-N) (General)20 kA
Maximum continuous operating voltage UC(L-PE) (General)350 V AC
Nominal discharge current In(8/20) µs (L-PE) (General)20 kA
Nominal discharge current In(8/20) µs (N-PE) (General)40 kA
Conductor cross section AWG (Indicator/remote signaling)12 ... 4
Maximum discharge current Imax(8/20) µs (L-N) (General)40 kA
Maximum discharge current Imax(8/20) µs (L-PE) (General)40 kA
Maximum discharge current Imax(8/20) µs (N-PE) (General)80 kA
Conductor cross section solid (Indicator/remote signaling)2.5 mm² ... 25 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 6 mm²

Product Description

Plug-in surge protection device, according to type 2/class II, for three-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact. Wit
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top