| Parameter | Value |
|---|---|
| GTIN | 4046356948043 |
| Orderkey | 2905341 |
| (General) | 63 A (gG / TWIN ferrule 2x 10mm²) |
| Catalog page | Page 47 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Connection data) | N-G |
| (UL specifications) | 14 ... 4 (flexible) |
| Custom tariff number | 85363030 |
| (Ambient conditions) | PBT-FR |
| (UL connection data) | EN 61643-11 2012 |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Type (Ambient conditions) | DIN rail module, two-section, divisible |
| Color (Ambient conditions) | light grey RAL 7035 |
| SPD Type (Connection data) | 4CA |
| Depth (Key Commercial Data) | 74.5 mm (incl. DIN rail 7.5 mm) |
| Width (Key Commercial Data) | 25.4 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| EN type (Ambient conditions) | T2 |
| Height (Key Commercial Data) | 89.9 mm |
| Nominal voltage UN (General) | 240 V AC (TN-S) |
| Nom. voltage (Connection data) | 240 V AC |
| Nominal frequency fN (General) | 50 Hz (60 Hz) |
| Residual current IPE (General) | ≤ 1 µA |
| Shock (operation) (Dimensions) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Rated load current IL (General) | 40 A (Biconnect M4 fork-type cable lug 6 mm²) |
| Response time tA(L-N) (General) | ≤ 25 ns |
| Response time tA(L-PE) (General) | ≤ 100 ns |
| Response time tA(N-PE) (General) | ≤ 100 ns |
| Degree of protection (Dimensions) | IP20 |
| Screw thread (Protective circuit) | M5 |
| TOV behavior at UT(L-N) (General) | 415 V AC (5 s / withstand mode) |
| Mounting type (Ambient conditions) | DIN rail: 35 mm |
| TOV behavior at UT(N-PE) (General) | 1200 V AC (200 ms / withstand mode) |
| Vibration (operation) (Dimensions) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| Nominal frequency (Connection data) | 50/60 Hz |
| Mode of protection (Connection data) | L-N |
| Residual voltage Ures(L-N) (General) | ≤ 1.5 kV (at In) |
| Weight per Piece (excluding packing) | 211.500 g |
| Housing material (Ambient conditions) | PA 6.6-FR 20% GF |
| Residual voltage Ures(N-PE) (General) | ≤ 0.5 kV (at In) |
| Stripping length (Protective circuit) | 16 mm |
| Tightening torque (UL specifications) | 40 lbf-in. ... 50 lbf-in. |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Connection method (Protective circuit) | Fork-type cable lug |
| Horizontal pitch (Key Commercial Data) | 1.4 Div. |
| Tightening torque (Protective circuit) | 4.5 Nm |
| Mode of protection (Ambient conditions) | L-N |
| Degree of pollution (Ambient conditions) | 2 |
| Number of positions (Ambient conditions) | 2 |
| Standards/regulations (UL connection data) | IEC 61643-11 2011 |
| Voltage protection level Up(L-N) (General) | ≤ 1.5 kV |
| Power distribution system (Connection data) | Single phase |
| Voltage protection level Up(L-PE) (General) | ≤ 1.9 kV |
| Voltage protection level Up(N-PE) (General) | ≤ 1.5 kV |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 80 °C |
| IEC power supply system (Ambient conditions) | TN-S |
| IEC test classification (Ambient conditions) | II |
| Short-circuit current rating ISCCR (General) | 25 kA (in case of 315 A gG backup fuse) |
| Max. backup fuse with branch wiring (General) | 315 A (gG) |
| Maximum continuous voltage UC(N-PE) (General) | 264 V AC |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Conductor cross section AWG (UL specifications) | 14 ... 2 (solid) |
| Conductor cross section AWG (Protective circuit) | 12 ... 4 |
| Nominal discharge current In(8/20) µs (General) | 20 kA |
| Conductor cross section solid (Protective circuit) | 2.5 mm² ... 25 mm² |
| Maximum discharge current Imax(8/20) µs (General) | 40 kA |
| Follow current interrupt rating Ifi(N-PE) (General) | 100 A (264 V AC) |
| Nominal discharge current In(L-G) (Connection data) | 20 kA |
| Nominal discharge current In(L-N) (Connection data) | 20 kA |
| Nominal discharge current In(N-G) (Connection data) | 20 kA |
| Surge protection fault message (Ambient conditions) | optical |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Conductor cross section flexible (Protective circuit) | 1.5 mm² ... 6 mm² |
| Max. backup fuse with V-type through wiring (General) | 40 A (gG / Biconnect M4 fork-type cable lug, 6 mm²) |
| Measured limiting voltage MLV (L-G) (Connection data) | 2080 V |
| Measured limiting voltage MLV (L-N) (Connection data) | 2000 V |
| Measured limiting voltage MLV (N-G) (Connection data) | 950 V |
| Maximum continuous operating voltage UC(L-N) (General) | 350 V AC |
| Maximum continuous operating voltage UC(L-PE) (General) | 350 V AC |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Maximum continuous operating voltage MCOV (L-G) (Connection data) | 350 V AC |
| Maximum continuous operating voltage MCOV (L-N) (Connection data) | 350 V AC |
| Maximum continuous operating voltage MCOV (N-G) (Connection data) | 264 V AC |
Technical specifications and performance data
Installation and operation guide