Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 48/12.5/O - VAL-MS-T1/T2 48/12.5/O 2906281 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 48/12.5/O

VAL-MS-T1/T2 48/12.5/O 2906281 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00USD
3820 in stock
Key Specifications
GTIN:4055626063065
Note:Made to Order (non-returnable)
Orderkey:2906281
(General):160 A AC (gG)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626063065
NoteMade to Order (non-returnable)
Orderkey2906281
(General)160 A AC (gG)
Catalog pagePage 39 (C-4-2017)
Packing unit12 pc
Country of originDE (Germany)
(Connection data)(L-) - G
Custom tariff number85363090
(Ambient conditions)(L+) - PE
(Protective circuit)10 ... 2 (UL)
(UL connection data)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Altitude (Dimensions)max. 2000 m
Minimum order quantity12 pc
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)black
Response time tA (General)≤ 25 ns
SPD Type (Connection data)1CA
Depth (Key Commercial Data)89.2 mm
Width (Key Commercial Data)17.5 mm
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)77.1 mm
Nominal voltage UN (General)-48 V DC (RRH)
TOV behavior at UT (General)100 V AC (5 s / withstand mode)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 0.6 mA
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
China RoHS (UL connection data)Environmentally Friendly Use Period = 50
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 0.4 kV (at In)
Response time tA(L-N) (General)≤ 25 ns
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Nominal voltage (Connection data)60 V DC
Response time tA(L-PEN) (General)≤ 25 ns
Screw thread (Protective circuit)M5
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data)L-L
Weight per Piece (excluding packing)149.000 g
Housing material (Ambient conditions)PBT
Stripping length (Protective circuit)16 mm
Tightening torque (UL specifications)30 lbf-in.
Voltage protection level Up (General)≤ 0.4 kV
Connection method (Protective circuit)Screw connection
Horizontal pitch (Key Commercial Data)1 Div.
Standby power consumption PC (General)≤ 45 mVA
Tightening torque (Protective circuit)4.5 Nm
Maximum continuous voltage UC (General)75 V AC
Mode of protection (Ambient conditions)L-PEN
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)1
Voltage protection level Up(L-N) (General)≤ 0.4 kV
Power distribution system (Connection data)Single phase
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)DC
IEC test classification (Ambient conditions)I / II
Short-circuit current rating ISCCR (General)25 kA
Voltage protection level Up(L-PEN) (General)≤ 0.4 kV
Max. backup fuse with branch wiring (General)160 A AC (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Nominal discharge current In (Connection data)20 kA
Conductor cross section AWG (UL specifications)10 ... 2
Measured limiting voltage MLV (Connection data)1240 V
Voltage protection rating VPR (Connection data)400 V
Conductor cross section AWG (Protective circuit)15 ... 2
Nominal discharge current In(8/20) µs (General)12.5 kA
Conductor cross section solid (Protective circuit)1.5 mm² ... 35 mm²
Maximum discharge current Imax(8/20) µs (General)30 kA
Nominal discharge current In(L-G) (Connection data)20 kA
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)1.5 mm² ... 25 mm²
Max. backup fuse with V-type through wiring (General)80 A AC (gG - 16 mm²)
Measured limiting voltage MLV (L-G) (Connection data)1240 V
Voltage protection rating VPR (L-N) (Connection data)400 V
Impulse discharge current (10/350) µs, charge (General)6.25 As
Maximum continuous operating voltage UC(L-PEN) (General)75 V AC
Maximum discharge current Imax(8/20) µs (L-N) (General)30 kA
Nominal discharge current In(L+) - (L-) (Connection data)20 kA
Maximum discharge current Imax(8/20) µs (L-PEN) (General)30 kA
Flammability rating according to UL 94 (Ambient conditions)V0
Maximum continuous operating voltage MCOV (Connection data)75 V AC
Measured limiting voltage MLV (L+) - (L-) (Connection data)1230 V
Impulse discharge current (10/350) µs (L-N), charge (General)6.25 As
Impulse discharge current (10/350) µs, peak value limp (General)12.5 kA
Impulse discharge current (10/350) µs, specific energy (General)39 kJ/Ω
Maximum continuous operating voltage MCOV (L-G) (Connection data)75 V AC
Maximum continuous operating voltage MCOV (L-N) (Connection data)75 V AC
Impulse discharge current (10/350) µs (L-N), specific energy (General)39 kJ/Ω
Maximum continuous operating voltage MCOV (L+) - (L-) (Connection data)100 V DC
Maximum continuous operating voltage MCOV (L+/L-) - G (Connection data)100 V DC
Impulse discharge current (10/350) µs (L-N), peak current value Iimp (General)12.5 kA

Product Description

Universal pluggable lightning current / surge arrester equipped with varistors for single-phase power supply networks with common N and PE (2-conductor system: L1, PEN), with remote indication contact
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top