Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 48/12.5/1+1V - VAL-MS-T1/T2 48/12.5/1+1V 2801532 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 48/12.5/1+1V

VAL-MS-T1/T2 48/12.5/1+1V 2801532 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00USD
4934 in stock
Key Specifications
GTIN:4046356811316
Orderkey:2801532
(General):130 V DC (5 s / withstand mode)
Catalog page:Page 38 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356811316
Orderkey2801532
(General)130 V DC (5 s / withstand mode)
Catalog pagePage 38 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)(L-) - G
Custom tariff number85363030
(Ambient conditions)PBT
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 25 ns
SPD Type (Connection data)1CA
Depth (Key Commercial Data)77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)35.6 mm
(Additional technical data)4.5 Nm (25 mm² ... 35 mm²)
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)89.8 mm
Nominal voltage UN (General)60 V AC ±10 % (TN-S)
TOV behavior at UT (General)100 V AC (5 s / withstand mode)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 0.6 mA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 0.4 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Nominal voltage (Connection data)60 V DC
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Mode of protection (Connection data)(L+) - (L-)
Weight per Piece (excluding packing)255.700 g
Housing material (Ambient conditions)PA 6.6
Tightening torque (UL specifications)30 lbf-in.
Horizontal pitch (Key Commercial Data)2 Div.
Standby power consumption PC (General)≤ 90 mVA
Maximum continuous voltage UC (General)75 V AC
Mode of protection (Ambient conditions)L-N
Degree of pollution (Ambient conditions)2
Screw thread (Additional technical data)M5
Standards/regulations (UL connection data)IEC 61643-11 2011
Voltage protection level Up(L-N) (General)≤ 0.4 kV
Voltage protection level Up(L-PE) (General)≤ 0.8 kV
Voltage protection level Up(N-PE) (General)≤ 0.4 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-S
IEC test classification (Ambient conditions)I / II
Short-circuit current rating ISCCR (General)25 kA
Stripping length (Additional technical data)16 mm
Connection method (Additional technical data)Fork-type cable lug
Max. backup fuse with branch wiring (General)160 A (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Tightening torque (Additional technical data)3 Nm (1,5 mm² ... 16 mm²)
Voltage protection level Up(L+) - PE (General)≤ 0.4 kV
Voltage protection level Up(L-) - PE (General)≤ 0.8 kV
Conductor cross section AWG (UL specifications)10 ... 2
Nominal discharge current In(8/20) µs (General)12.5 kA
Voltage protection level Up(L+) - (L-) (General)≤ 0.4 kV
Maximum discharge current Imax(8/20) µs (General)30 kA
Total discharge current Itotal(8/20) µs (General)50 kA
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General)12.5 kA
Max. backup fuse with V-type through wiring (General)80 A (gG - 16 mm²)
Short-circuit current rating (SCCR) (Connection data)5 kA
Nominal discharge current In(L+) - G (Connection data)20 kA
Nominal discharge current In(L-) - G (Connection data)20 kA
Conductor cross section AWG (Additional technical data)15 ... 2
Voltage protection rating VPR (L-) -G (Connection data)600 V
Impulse discharge current (10/350) µs, charge (General)6.25 As
Voltage protection rating VPR (L+) - G (Connection data)400 V
Conductor cross section solid (Additional technical data)1.5 mm² ... 35 mm²
Nominal discharge current In(L+) - (L-) (Connection data)20 kA
Flammability rating according to UL 94 (Ambient conditions)V-0
Voltage protection rating VPR (L+) - (L-) (Connection data)400 V
Conductor cross section flexible (Additional technical data)1.5 mm² ... 16 mm²
Maximum discharge current Imax(8/20) µs (Protective circuit)65 kA
Impulse discharge current (10/350) µs, peak value limp (General)12.5 kA
Impulse discharge current (10/350) µs, specific energy (General)39 kJ/Ω
Maximum continuous operating voltage MCOV (L+) - G (Connection data)100 V DC
Maximum continuous operating voltage MCOV (L-) - G (Connection data)100 V DC
Maximum continuous operating voltage MCOV (L+) - (L-) (Connection data)100 V DC

Product Description

Universal pluggable lightning/surge arrester with varistors for -48VDC applications where the return conductor (positive pole) has been grounded, without risk assessment for lightning protection class
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top