Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 335/12.5/4+0 - VAL-MS-T1/T2 335/12.5/4+0 2800645 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 335/12.5/4+0

VAL-MS-T1/T2 335/12.5/4+0 2800645 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00USD
4595 in stock
Key Specifications
:T1 / T2
Note:2011
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
T1 / T2
Note2011
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth77.5 mm (incl. DIN rail 7.5 mm)
Width71.2 mm
Height89.8 mm
EN typeT1 / T2
Altitude≤ 2000 m (amsl)
SPD Type4CA
Product typeArrester combination
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Product familyVALVETRAB MS
Nominal voltage415/240 V AC
Open side panelNo
Article revision09
Horizontal pitch4 Div.
Housing materialPA 6.6
Pollution degree2
Response time tA≤ 25 ns
Stripping length16 mm
Connection methodScrew connection
Nominal frequency50/60 Hz
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (1.5 mm² ... 16 mm²)
Mode of protectionL-PE
Nominal voltage UN240/415 V AC (TN-S)
TOV behavior at UT415 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action3L-N/PE
Insulating materialPA 6.6/PBT
Number of positions4
Degree of protectionIP20 (only when all terminal points are used)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 3.2 mA
CTI value of material600
Rated load current IL80 A
Residual voltage Ures≤ 1.2 kV (at In)
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN-S
IEC test classificationI / II
Standards/specificationsIEC 61643-11
Power distribution systemWye
Conductor cross section AWG15 ... 2
Voltage protection level Up≤ 1.2 kV
Standby power consumption PC≤ 1080 mVA
Conductor cross section rigid1.5 mm² ... 35 mm²
Maximum continuous voltage UC335 V AC
Surge protection fault messageoptical
Ambient temperature (operation)-40 °C ... 80 °C
Conductor cross section flexible1.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(L-L)20 kA
Nominal discharge current In(L-N)20 kA
Nominal discharge current In(N-G)20 kA
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring160 A (gG)
Measured limiting voltage MLV (L-G)2630 V
Measured limiting voltage MLV (L-L)3650 V
Measured limiting voltage MLV (L-N)3650 V
Measured limiting voltage MLV (N-G)2630 V
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs12.5 kA
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs50 kA
Total discharge current Itotal(8/20) µs200 kA
Max. backup fuse with V-type through wiring80 A (gG - 16 mm²)
Total discharge current Itotal(10/350) µs50 kA
Impulse discharge current (10/350) µs, charge6.5 As
Maximum continuous operating voltage MCOV (L-G)335 V AC
Maximum continuous operating voltage MCOV (L-L)670 V AC
Maximum continuous operating voltage MCOV (L-N)670 V AC
Maximum continuous operating voltage MCOV (N-G)335 V AC
Impulse discharge current (10/350) µs, peak value limp12.5 kA
Impulse discharge current (10/350) µs, specific energy39 kJ/Ω

Product Description

Universal pluggable lightning current / surge arrester equipped with varistors for three-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE).
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top