Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 335/12.5/3+0 - VAL-MS-T1/T2 335/12.5/3+0 2800189 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 335/12.5/3+0

VAL-MS-T1/T2 335/12.5/3+0 2800189 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00USD
4916 in stock
Key Specifications
GTIN:4046356518604
Orderkey:2800189
(General):457 V AC (120 min / safe failure mode)
Catalog page:Page 37 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356518604
Orderkey2800189
(General)457 V AC (120 min / safe failure mode)
Catalog pagePage 37 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)L-G
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)4.5 Nm (25 mm² ... 35 mm²)
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 25 ns
SPD Type (Connection data)4CA
Depth (Key Commercial Data)77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)53.4 mm
(Standards and Regulations)No hazardous substances above threshold values
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)89.8 mm
Nominal voltage UN (General)240/415 V AC (TN-C)
TOV behavior at UT (General)415 V AC (5 s / withstand mode)
Nom. voltage (Connection data)240 V AC
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 2400 µA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 1.2 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M5
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)L-L
Weight per Piece (excluding packing)527.800 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)16 mm
Tightening torque (UL specifications)30 lbf-in.
Voltage protection level Up (General)≤ 1.2 kV
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Protective circuit)Fork-type cable lug
Horizontal pitch (Key Commercial Data)3 Div.
Standby power consumption PC (General)≤ 810 mVA
Tightening torque (Protective circuit)3 Nm (1,5 mm² ... 16 mm²)
Maximum continuous voltage UC (General)335 V AC
Mode of protection (Ambient conditions)L-PEN
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)3
Standards/regulations (UL connection data)IEC 61643-11 2011
Power distribution system (Connection data)Delta
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-C
IEC test classification (Ambient conditions)I / II
Short-circuit current rating ISCCR (General)25 kA
Max. backup fuse with branch wiring (General)160 A (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Conductor cross section AWG (UL specifications)10 ... 2
Conductor cross section AWG (Protective circuit)15 ... 2
Nominal discharge current In(8/20) µs (General)12.5 kA
Conductor cross section solid (Protective circuit)1.5 mm² ... 35 mm²
Maximum discharge current Imax(8/20) µs (General)50 kA
Total discharge current Itotal(8/20) µs (General)150 kA
Nominal discharge current In(L-G) (Connection data)20 kA
Nominal discharge current In(L-L) (Connection data)20 kA
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General)37.5 kA
Conductor cross section flexible (Protective circuit)1.5 mm² ... 16 mm²
Max. backup fuse with V-type through wiring (General)80 A (gG - 16 mm²)
Measured limiting voltage MLV (L-G) (Connection data)2630 V
Measured limiting voltage MLV (L-L) (Connection data)3570 V
Impulse discharge current (10/350) µs, charge (General)6.25 As
Flammability rating according to UL 94 (Ambient conditions)V-0
Impulse discharge current (10/350) µs, peak value limp (General)12.5 kA
Impulse discharge current (10/350) µs, specific energy (General)39 kJ/Ω
Maximum continuous operating voltage MCOV (L-G) (Connection data)335 V AC
Maximum continuous operating voltage MCOV (L-L) (Connection data)335 V AC

Product Description

Universal plug-in beam current/surge charger equipped with varistors for three-phase power supply networks with common N and PE (4-conductor system: L1, L2, L3, PEN).
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top