VAL-MS-T1/T2 335/12.5/1+0-FM - VAL-MS-T1/T2 335/12.5/1+0-FM 2801042 PHOENIX CONTACT Lightning/surge arrester type 1/2
In Stock Hot Product

VAL-MS-T1/T2 335/12.5/1+0-FM

VAL-MS-T1/T2 335/12.5/1+0-FM 2801042 PHOENIX CONTACT Lightning/surge arrester type 1/2

$0.00USD
3926 in stock
Key Specifications
GTIN:4046356698153
Orderkey:2801042
(General):≤ 0.9 kV (at 3 kA)
Catalog page:Page 37 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356698153
Orderkey2801042
(General)≤ 0.9 kV (at 3 kA)
Catalog pagePage 37 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)EN 61643-11 2012
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)1 A DC
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 25 ns
Depth (Key Commercial Data)77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.6 mm
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)96.8 mm
Nominal voltage UN (General)240 V AC (TN-C, TN-S)
TOV behavior at UT (General)415 V AC (5 s / withstand mode)
(Indicator/remote signaling)4.5 Nm (25 mm² ... 35 mm²)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 800 µA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 1.2 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Weight per Piece (excluding packing)210.500 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)7 mm
Voltage protection level Up (General)≤ 1.2 kV
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)1 Div.
Operating current (Protective circuit)5 mA AC ... 1 A AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Standby power consumption PC (General)≤ 270 mVA
Tightening torque (Protective circuit)0.25 Nm
Maximum continuous voltage UC (General)335 V AC
Mode of protection (Ambient conditions)L-N
Standards/regulations (Connection data)IEC 61643-11 2011
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Screw thread (Indicator/remote signaling)M5
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-S
IEC test classification (Ambient conditions)I / II
Short-circuit current rating ISCCR (General)25 kA
Max. backup fuse with branch wiring (General)160 A (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Tightening torque (Indicator/remote signaling)3 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (Protective circuit)28 ... 16
Nominal discharge current In(8/20) µs (General)12.5 kA
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General)50 kA
Total discharge current Itotal(8/20) µs (General)12.5 kA
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General)12.5 kA
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General)80 A (gG - 16 mm²)
Conductor cross section AWG (Indicator/remote signaling)15 ... 2
Impulse discharge current (10/350) µs, charge (General)6.25 As
Conductor cross section solid (Indicator/remote signaling)1.5 mm² ... 35 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 16 mm²
Impulse discharge current (10/350) µs, peak value limp (General)12.5 kA
Impulse discharge current (10/350) µs, specific energy (General)39 kJ/Ω

Product Description

Universal pluggable lightning current / surge arrester equipped with varistors for single-phase power supply networks with common N and PE (2-conductor system: L1, PEN), with remote indication contact
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty