:I
Note:Nominal voltage UN = 120 V AC/240 V AC split-phase (separate GND)
Type:DIN rail module, two-section, divisible
Depth:77.5 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
I
NoteNominal voltage UN = 120 V AC/240 V AC split-phase (separate GND)
TypeDIN rail module, two-section, divisible
Depth77.5 mm (incl. DIN rail 7.5 mm)
Width35.6 mm
Height96.8 mm
EN typeT1 / T2
Altitude≤ 2000 m (amsl)
SPD Type4CA
Product typeArrester combination
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Product familyVALVETRAB MS
Connection nameRemote fault indicator contact
Nominal voltage120 V AC
Open side panelNo
Horizontal pitch2 Div.
Housing materialPA 6.6
Pollution degree2
Stripping length16 mm
Connection methodScrew connection
Nominal frequency50/60 Hz
Operating current5 mA AC ... 1.5 A AC
Operating voltage5 V AC ... 250 V AC
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (1.5 mm² ... 16 mm²)
Mode of protectionL-N
Nominal voltage UN120 V AC (TN-S)
Switching functionChangeover contact
Dimensional drawing
Direction of action1L-N & N-PE
Insulating materialPA 6.6/PBT
AC operating current1 A AC
Degree of protectionIP20 (only when all terminal points are used)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 5 µA
CTI value of material600
Rated load current IL80 A
Response time tA(L-N)≤ 25 ns
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
IEC power supply systemTT
IEC test classificationI / II
TOV behavior at UT(L-N)208 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Power distribution systemSingle phase
Residual voltage Ures(L-N)≤ 0.8 kV (at In)
Conductor cross section AWG15 ... 2
Residual voltage Ures(L-PE)≤ 2 kV (at In)
Residual voltage Ures(N-PE)≤ 0.6 kV (at In)
Standby power consumption PC≤ 140 mVA
Conductor cross section rigid1.5 mm² ... 35 mm²
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 80 °C
Conductor cross section flexible1.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Voltage protection level Up(L-N)≤ 0.8 kV
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(L-N)20 kA
Nominal discharge current In(N-G)20 kA
Voltage protection level Up(L-PE)≤ 2 kV
Voltage protection level Up(N-PE)≤ 1.7 kV
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring160 A (gG)
Measured limiting voltage MLV (L-G)3160 V
Measured limiting voltage MLV (L-N)2200 V
Measured limiting voltage MLV (N-G)2600 V
Flammability rating according to UL 94V-0
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs50 kA
Follow current interrupt rating Ifi(N-PE)100 A
Total discharge current Itotal(8/20) µs50 kA
Max. backup fuse with V-type through wiring80 A (gG - 16 mm²)
Total discharge current Itotal(10/350) µs25 kA
Maximum continuous operating voltage UC(L-N)175 V AC
Nominal discharge current In(8/20) µs (L-N)12.5 kA
Maximum continuous operating voltage UC(L-PE)175 V AC
Maximum continuous operating voltage UC(N-PE)264 V AC
Nominal discharge current In(8/20) µs (L-PE)12.5 kA
Nominal discharge current In(8/20) µs (N-PE)50 kA
Maximum continuous operating voltage MCOV (L-G)175 V AC
Maximum continuous operating voltage MCOV (L-N)175 V AC
Maximum continuous operating voltage MCOV (N-G)264 V AC
Impulse discharge current (10/350) µs (L-PE), charge6.25 As
Impulse discharge current (10/350) µs (N-PE), charge25 As
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), specific energy625 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp50 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA