Service time: Monday to Friday 9:00-18:00
VAL-MS-T1/T2 1000DC-PV/3+V/32 - VAL-MS-T1/T2 1000DC-PV/3+V/32 1044183 PHOENIX CONTACT Lightning current arrester/surge protective device for..
In Stock Hot Product

VAL-MS-T1/T2 1000DC-PV/3+V/32

VAL-MS-T1/T2 1000DC-PV/3+V/32 1044183 PHOENIX CONTACT Lightning current arrester/surge protective device for..

$0.00USD
4447 in stock
Key Specifications
GTIN:4055626620657
Orderkey:1044183
(Drawings):
Catalog page:Page 50 (C-4-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626620657
Orderkey1044183
(Drawings)
Catalog pagePage 50 (C-4-2019)
Packing unit1
Note (General)The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Depth (Drawings)65.7 mm (incl. DIN rail 7.5 mm)
Width (Drawings)71.2 mm
ETIM 5.0 (eCl@ss)EC000381
ETIM 6.0 (eCl@ss)EC000381
ETIM 7.0 (eCl@ss)EC000381
Height (Drawings)89.8 mm
Custom tariff number85363030
(Ambient conditions)PBT-FR
Altitude (Dimensions)≤ 3000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
(Additional descriptions)≤ 700 µA AC
Color (Ambient conditions)jet black RAL 9005
Horizontal pitch (Drawings)4 Div.
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
EN type (Ambient conditions)T1 / T2
eCl@ss 4.0 (Classifications)27130800
eCl@ss 4.1 (Classifications)27130800
eCl@ss 5.0 (Classifications)27130800
eCl@ss 5.1 (Classifications)27130800
eCl@ss 6.0 (Classifications)27130800
eCl@ss 7.0 (Classifications)27130802
eCl@ss 8.0 (Classifications)27130802
eCl@ss 9.0 (Classifications)27130802
Dimensional drawing (Drawings)
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Accessibility (Ambient conditions)Accessible
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (5-500 Hz/2.5 h/XYZ)
Housing material (Ambient conditions)PA 6.6-FR
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Mode of protection (Ambient conditions)(DC+) - (DC-)
Standards/regulations (Connection data)EN 50539-11 2013
Degree of pollution (Ambient conditions)2
SPD failure behavior (Ambient conditions)OCM (Open-circuit mode)
(Protective circuit DC voltage side (DC))4.5 Nm (25 mm² ... 35 mm²)
Installation location (Ambient conditions)Interior
Response time tA (Additional descriptions)≤ 25 ns
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
IEC test classification (Ambient conditions)PV I / II
Connection configuration (Ambient conditions)Y configuration
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Residual current IPE (Additional descriptions)≤ 40 µA DC
Rated load current IL (Additional descriptions)80 A
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Insulation resistance Riso (Additional descriptions)> 5 GΩ (at 500 V DC)
Screw thread (Protective circuit DC voltage side (DC))M5
Standby power consumption PC (Additional descriptions)≤ 25 mVA
Stripping length (Protective circuit DC voltage side (DC))16 mm
Connection method (Protective circuit DC voltage side (DC))Fork-type cable lug
Continuous operating current ICPV (Additional descriptions)< 20 µA
Flammability rating according to UL 94 (Ambient conditions)V-0
Tightening torque (Protective circuit DC voltage side (DC))3 Nm (1.5 mm² ... 16 mm²)
Short-circuit current rating ISCPV (Additional descriptions)2000 A
Distance between live and grounded parts (Ambient conditions)8 mm
Nominal discharge current (8/20) µs (Additional descriptions)15 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions)40 kA
Installation location of the disconnect device (Ambient conditions)Internal
Maximum continuous operating voltage UCPV (Additional descriptions)1170 V DC
Total discharge current Itotal(8/20) µs (Additional descriptions)40 kA
Conductor cross section AWG (Protective circuit DC voltage side (DC))15 ... 2
Total discharge current Itotal(10/350) µs (Additional descriptions)10 kA
Conductor cross section solid (Protective circuit DC voltage side (DC))1.5 mm² ... 35 mm²
Impulse discharge current (10/350) µs, charge (Additional descriptions)2.5 As
Conductor cross section flexible (Protective circuit DC voltage side (DC))1.5 mm² ... 16 mm²
Impulse discharge current (10/350) µs, peak value limp (Additional descriptions)5 kA
Impulse discharge current (10/350) µs, specific energy (Additional descriptions)6.25 kJ/Ω

Product Description

Lightning current/surge arrester for 1000 V DC 2-pole isolated DC systems, for rail mounting, 4-pole base element, four plug-in protection elements with temperature control, status signaling on each c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawing

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide