| Parameter | Value |
|---|---|
| GTIN | 4046356430869 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2805318 |
| Catalog page | Page 62 (C-4-2017) |
| Packing unit | 10 pc |
| Country of origin | DE (Germany) |
| (Connection data) | (L+) - (L-) |
| (UL specifications) | EN 61643-11 2012 |
| Custom tariff number | 85363030 |
| (Ambient conditions) | L-L |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Type (Ambient conditions) | DIN rail module, two-section, divisible |
| (Additional descriptions) | ≤ 0.6 kV (at 3 kA) |
| Color (Ambient conditions) | jet black RAL 9005 |
| SPD Type (Connection data) | 4CA |
| Depth (Key Commercial Data) | 55.3 mm |
| Width (Key Commercial Data) | 17.5 mm |
| EN type (Ambient conditions) | T2 |
| Height (Key Commercial Data) | 52.4 mm |
| Nom. voltage (Connection data) | 48 V AC |
| Shock (operation) (Dimensions) | 25g |
| Degree of protection (Dimensions) | IP20 |
| Nominal voltage (Connection data) | 60 V DC |
| Mounting type (Ambient conditions) | on base element |
| Vibration (operation) (Dimensions) | 5g |
| Nominal frequency (Connection data) | 50/60 Hz |
| Mode of protection (Connection data) | L-N |
| Weight per Piece (excluding packing) | 31.520 g |
| Housing material (Ambient conditions) | PA 6.6 |
| Connection method (Protective circuit) | pluggable |
| Horizontal pitch (Key Commercial Data) | 1 Div. |
| Mode of protection (Ambient conditions) | L-PE |
| Degree of pollution (Ambient conditions) | 2 |
| Number of positions (Ambient conditions) | 1 |
| Standards/regulations (UL specifications) | IEC 61643-11 2011 |
| Response time tA (Additional descriptions) | ≤ 100 ns |
| Power distribution system (Connection data) | Single phase |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 80 °C |
| IEC test classification (Ambient conditions) | II |
| Nominal voltage UN (Additional descriptions) | 5 V AC ... 48 V AC |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Nominal frequency fN (Additional descriptions) | 50 Hz (60 Hz) |
| Residual current IPE (Additional descriptions) | ≤ 5 µA |
| Residual voltage Ures (Additional descriptions) | ≤ 0.45 kV (at In) |
| Nominal discharge current In(L-N) (Connection data) | 10 kA |
| Surge protection fault message (Ambient conditions) | optical |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Residual voltage Ures(L-L) (Additional descriptions) | ≤ 0.9 kV (at In) |
| Measured limiting voltage MLV (L-N) (Connection data) | 1760 V |
| Voltage protection level Up (Additional descriptions) | ≤ 1.4 kV |
| Standby power consumption PC (Additional descriptions) | ≤ 1 mVA |
| Maximum continuous voltage UC (Additional descriptions) | 75 V AC |
| Nominal discharge current In(L+) - (L-) (Connection data) | 10 kA |
| Voltage protection level Up(L-L) (Additional descriptions) | ≤ 1.8 kV |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Measured limiting voltage MLV (L+) - (L-) (Connection data) | 1760 V |
| Short-circuit current rating ISCCR (Additional descriptions) | 10 kA |
| Max. backup fuse with branch wiring (Additional descriptions) | 63 A (gG) |
| Nominal discharge current In(8/20) µs (Additional descriptions) | 10 kA |
| Maximum continuous operating voltage MCOV (L-N) (Connection data) | 75 V AC |
| Maximum discharge current Imax(8/20) µs (Additional descriptions) | 20 kA |
| Maximum continuous operating voltage MCOV (L+) - (L-) (Connection data) | 100 V DC |
| Front of wave sparkover voltage at 6 kV (1.2/50) µs (Additional descriptions) | ≤ 1.4 kV |