Service time: Monday to Friday 9:00-18:00
VAL-MS 350 VF-RW/3+0-FM/40 - VAL-MS 350 VF-RW/3+0-FM/40 1050284 PHOENIX CONTACT Type 2 surge arrester
In Stock Hot Product

VAL-MS 350 VF-RW/3+0-FM/40

VAL-MS 350 VF-RW/3+0-FM/40 1050284 PHOENIX CONTACT Type 2 surge arrester

$0.00USD
4109 in stock
Key Specifications
GTIN:4055626666501
Note:Made to Order (non-returnable)
Orderkey:1050284
Packing unit:40 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626666501
NoteMade to Order (non-returnable)
Orderkey1050284
Packing unit40 pc
Country of originDE (Germany)
(Connection data)EN 61643-11 2012
Custom tariff number85363090
(Ambient conditions)PBT
(Protective circuit)1 A DC
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Minimum order quantity40 pc
Type (Ambient conditions)DIN rail module, two-section, divisible
(Additional descriptions)440 V AC (120 min / withstand mode)
Color (Ambient conditions)jet black RAL 9005
Depth (Key Commercial Data)65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)53.4 mm
EN type (Ambient conditions)T2
Height (Key Commercial Data)98.7 mm
(Indicator/remote signaling)4.5 Nm (25 mm² ... 35 mm²)
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Weight per Piece (excluding packing)348.080 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)7 mm
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)3 Div.
Operating current (Protective circuit)5 mA AC ... 1.5 A AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Tightening torque (Protective circuit)0.25 Nm
Mode of protection (Ambient conditions)L-PE
Standards/regulations (Connection data)IEC 61643-11 2011
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)3
Screw thread (Indicator/remote signaling)M5
Response time tA (Additional descriptions)≤ 100 ns
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC test classification (Ambient conditions)II
Nominal voltage UN (Additional descriptions)240/415 V AC (TN-C)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Nominal frequency fN (Additional descriptions)50 Hz (60 Hz)
Residual current IPE (Additional descriptions)≤ 5 µA
Tightening torque (Indicator/remote signaling)3 Nm (1,5 mm² ... 16 mm²)
Rated load current IL (Additional descriptions)80 A
Residual voltage Ures (Additional descriptions)≤ 1.35 kV (at In)
Conductor cross section AWG (Protective circuit)28 ... 16
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
TOV behavior at UT(L-PEN) (Additional descriptions)415 V AC (5 s / withstand mode)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Voltage protection level Up (Additional descriptions)≤ 1.5 kV
Standby power consumption PC (Additional descriptions)≤ 6 mVA
Maximum continuous voltage UC (Additional descriptions)350 V AC
Conductor cross section AWG (Indicator/remote signaling)15 ... 2
Conductor cross section solid (Indicator/remote signaling)1.5 mm² ... 35 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Short-circuit current rating ISCCR (Additional descriptions)25 kA
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 16 mm²
Max. backup fuse with branch wiring (Additional descriptions)125 A (gG)
Nominal discharge current In(8/20) µs (Additional descriptions)10 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions)20 kA
Max. backup fuse with V-type through wiring (Additional descriptions)80 A (gG)
Impulse discharge current (10/350) µs, charge (Additional descriptions)1.25 As
Front of wave sparkover voltage at 6 kV (1.2/50) µs (Additional descriptions)≤ 1.5 kV
Impulse discharge current (10/350) µs, peak value limp (Additional descriptions)2.5 kA
Impulse discharge current (10/350) µs, specific energy (Additional descriptions)1.56 kJ/Ω

Product Description

Plug-in leakage current proof surge arrester with increased lightning current shunt capability, for three-phase power supply networks, with N and PE in a common conductor (4-conductor system: L1, L2,L
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top