Key Specifications
:T2
Note:2011
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
T2
Note2011
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth65.7 mm (incl. DIN rail 7.5 mm)
Width71 mm
Height98.7 mm
EN typeT2
Altitude≤ 2000 m (amsl)
SPD Type4CA
Product typeSurge arrester
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Product familyVALVETRAB MS
Connection nameRemote fault indicator contact
Nominal voltage240/415 V AC
Article revision21
Horizontal pitch4 Div.
Housing materialPA 6.6
Pollution degree2
Stripping length16 mm
Connection methodScrew connection
Nominal frequency50/60 Hz
Operating current5 mA AC ... 750 mA AC
Operating voltage5 V AC ... 250 V AC
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (1.5 mm² ... 16 mm²)
Mode of protectionL-N
Nominal voltage UN240/415 V AC (TN-S)
Switching functionChangeover contact
Dimensional drawing
Direction of action3L-N & N-PE
Insulating materialPA 6.6/PBT
Number of positions4
AC operating current1 A AC
Degree of protectionIP20 (only when all terminal points are used)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 5 µA
CTI value of material600
Rated load current IL80 A
Response time tA(L-N)≤ 25 ns
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
IEC power supply systemTN-S
IEC test classificationII
TOV behavior at UT(L-N)415 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Power distribution systemWye
Residual voltage Ures(L-N)≤ 1.6 kV (at In)
Conductor cross section AWG15 ... 2
Residual voltage Ures(L-PE)≤ 1.9 kV (at In)
Residual voltage Ures(N-PE)≤ 0.4 kV (at In)
Standby power consumption PC≤ 450 mVA
Conductor cross section rigid1.5 mm² ... 35 mm²
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 80 °C
Conductor cross section flexible1.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Voltage protection level Up(L-N)≤ 1.6 kV
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(L-L)20 kA
Nominal discharge current In(L-N)20 kA
Nominal discharge current In(N-G)20 kA
Voltage protection level Up(L-PE)≤ 1.9 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring125 A (gG)
Measured limiting voltage MLV (L-G)2720 V
Measured limiting voltage MLV (L-L)2900 V
Measured limiting voltage MLV (L-N)2030 V
Measured limiting voltage MLV (N-G)1370 V
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs20 kA
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs40 kA
Follow current interrupt rating Ifi(N-PE)100 A
Max. backup fuse with V-type through wiring80 A (gG)
Maximum continuous operating voltage UC(L-N)335 V AC
Maximum continuous operating voltage UC(L-PE)335 V AC
Maximum continuous operating voltage UC(N-PE)260 V AC
Maximum continuous operating voltage MCOV (L-G)320 V AC
Maximum continuous operating voltage MCOV (L-L)640 V AC
Maximum continuous operating voltage MCOV (L-N)320 V AC
Maximum continuous operating voltage MCOV (N-G)260 V AC

Product Description

Surge arrester consisting of a base element with FM remote indication contact and plug-in protections, for installation on NS 35/7.5, nominal voltage: 320 V AC, circuit "3 + 1"
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top