Service time: Monday to Friday 9:00-18:00
VAL-MS 230 ST - VAL-MS 230 ST 2798844 PHOENIX CONTACT Type 2 surge protection plug
In Stock Hot Product

VAL-MS 230 ST

VAL-MS 230 ST 2798844 PHOENIX CONTACT Type 2 surge protection plug

$0.00USD
4440 in stock
Key Specifications
:T2
Note:2011
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
T2
Note2011
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth55.3 mm
Width17.5 mm
Height52.4 mm
EN typeT2
Altitude≤ 2000 m (amsl)
SPD Type4CA
Product typeReplacement plug
Mounting typeon base element
Material groupI
Product familyVALVETRAB MS
Nominal voltage230 V AC
Article revision27
Horizontal pitch1 Div.
Housing materialPA 6.6
Pollution degree2
Response time tA≤ 25 ns
Connection methodpluggable
Nominal frequency50/60 Hz
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Mode of protectionL-N
Nominal voltage UN240/415 V AC (TN)
TOV behavior at UT335 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action1L-N/PE
Insulating materialPA 6.6
Number of positions1
Degree of protectionIP20
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 0.45 mA
CTI value of material600
Residual voltage Ures≤ 1.35 kV (at In)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN
IEC test classificationII
Standards/specificationsIEC 61643-11
Power distribution systemSingle phase
Voltage protection level Up≤ 1.35 kV
Standby power consumption PC≤ 120 mVA
Maximum continuous voltage UC275 V AC
Surge protection fault messageoptical
Ambient temperature (operation)-40 °C ... 80 °C
Permissible humidity (operation)5 % ... 95 %
Nominal discharge current In(L-N)20 kA
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring125 A (gG)
Measured limiting voltage MLV (L-N)1910 V
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs20 kA
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum discharge current Imax(8/20) µs40 kA
Maximum continuous operating voltage MCOV (L-N)275 V AC
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.10

Product Description

Plug-in type 2 surge protection with high-power varistor for VAL-MS base element, with thermal control, optical fault indication. Execution: 230 V AC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty