Service time: Monday to Friday 9:00-18:00
VAL-MS 230/FM - VAL-MS 230/FM 2839130 PHOENIX CONTACT Type 2 surge arrester
In Stock Hot Product

VAL-MS 230/FM

VAL-MS 230/FM 2839130 PHOENIX CONTACT Type 2 surge arrester

$0.00USD
3858 in stock
Key Specifications
GTIN:4017918182595
Orderkey:2839130
(General):440 V AC (120 min / safe failure mode)
Catalog page:Page 44 (C-6-2015)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918182595
Orderkey2839130
(General)440 V AC (120 min / safe failure mode)
Catalog pagePage 44 (C-6-2015)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)1 A DC
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 25 ns
SPD Type (Connection data)4CA
Depth (Key Commercial Data)65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.6 mm
EN type (Ambient conditions)T2
Height (Key Commercial Data)96.8 mm
Nominal voltage UN (General)240/415 V AC (TN)
TOV behavior at UT (General)335 V AC (5 s / withstand mode)
(Indicator/remote signaling)4.5 Nm (25 mm² ... 35 mm²)
Nom. voltage (Connection data)230 V AC
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 0.45 mA
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 1.35 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)L-N
Weight per Piece (excluding packing)135.200 g
Housing material (Ambient conditions)PA 6.6
Operating current (UL specifications)1 A AC
Operating voltage (UL specifications)125 V AC
Stripping length (Protective circuit)7 mm
Tightening torque (UL specifications)4 lbf-in.
Voltage protection level Up (General)≤ 1.35 kV
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)1 Div.
Operating current (Protective circuit)5 mA AC ... 1 A AC
Operating voltage (Protective circuit)5 V AC ... 250 V AC
Standby power consumption PC (General)≤ 120 mVA
Tightening torque (Protective circuit)0.25 Nm
Maximum continuous voltage UC (General)275 V AC
Mode of protection (Ambient conditions)L-N
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)1
Screw thread (Indicator/remote signaling)M5
Standards/regulations (UL connection data)IEC 61643-11 2011
Power distribution system (Connection data)Single phase
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN
IEC test classification (Ambient conditions)II
Short-circuit current rating ISCCR (General)25 kA
Max. backup fuse with branch wiring (General)125 A (gG)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)16 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Tightening torque (Indicator/remote signaling)3 Nm (1,5 mm² ... 16 mm²)
Conductor cross section AWG (Protective circuit)28 ... 16
Nominal discharge current In(8/20) µs (General)20 kA
Tightening torque (UL indicator/remote signaling)30 lbf-in.
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Maximum discharge current Imax(8/20) µs (General)40 kA
Nominal discharge current In(L-N) (Connection data)20 kA
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Max. backup fuse with V-type through wiring (General)80 A (gG)
Measured limiting voltage MLV (L-N) (Connection data)1900 V
Conductor cross section AWG (Indicator/remote signaling)15 ... 2
Conductor cross section solid (Indicator/remote signaling)1.5 mm² ... 35 mm²
Conductor cross section AWG (UL indicator/remote signaling)10 ... 2
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 16 mm²
Maximum continuous operating voltage MCOV (L-N) (Connection data)275 V AC

Product Description

Surge arrester consisting of a base element with FM remote indication contact and plug-in protection with high-power varistor, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 1 channel.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top