| Parameter | Value |
|---|---|
| GTIN | 4055626540504 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1033727 |
| Packing unit | 3 pc |
| Country of origin | DE (Germany) |
| (Connection data) | (DC-) - G |
| Custom tariff number | 85354000 |
| (Ambient conditions) | PBT-FR |
| Altitude (Dimensions) | ≤ 3000 m (amsl (above mean sea level)) |
| Minimum order quantity | 3 pc |
| Type (Ambient conditions) | Male |
| (Additional descriptions) | ≤ 3 kV (at 30 kA) |
| Color (Ambient conditions) | jet black RAL 9005 |
| SPD Type (Connection data) | 1CA |
| Depth (Key Commercial Data) | 55.3 mm |
| Width (Key Commercial Data) | 17.5 mm |
| EN type (Ambient conditions) | T2 |
| Height (Key Commercial Data) | 52.4 mm |
| Shock (operation) (Dimensions) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Degree of protection (Dimensions) | IP20 |
| Nominal voltage (Connection data) | 1500 V DC |
| Accessibility (Ambient conditions) | Accessible |
| Mounting type (Ambient conditions) | on base element |
| Vibration (operation) (Dimensions) | 5g (5-500 Hz/2.5 h/XYZ) |
| Mode of protection (Connection data) | (DC+) - (DC-) |
| Weight per Piece (excluding packing) | 84.500 g |
| Housing material (Ambient conditions) | PA 6.6-FR |
| Horizontal pitch (Key Commercial Data) | 1 Div. |
| Degree of pollution (Ambient conditions) | 2 |
| SPD failure behavior (Ambient conditions) | OCM (Open-circuit mode) |
| Standards/regulations (UL specifications) | EN 50539-11 2013 |
| Installation location (Ambient conditions) | Inside |
| Response time tA (Additional descriptions) | ≤ 25 ns |
| Power distribution system (Connection data) | DC PV |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 85 °C |
| IEC power supply system (Ambient conditions) | DC |
| IEC test classification (Ambient conditions) | PV II |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Nominal discharge current In (Connection data) | 10 kA |
| Residual voltage Ures (Additional descriptions) | ≤ 2.5 kV (at In) |
| Voltage protection rating VPR (Connection data) | 4 kV |
| Surge protection fault message (Ambient conditions) | optical |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Short-circuit current rating (SCCR) (Connection data) | 50 kA |
| Voltage protection level Up (Additional descriptions) | ≤ 2.5 kV |
| Standby power consumption PC (Additional descriptions) | ≤ 250 mVA |
| Connection method (Protective circuit DC voltage side (DC)) | pluggable |
| Continuous operating current ICPV (Additional descriptions) | < 350 µA |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Maximum continuous operating voltage MCOV (Connection data) | 1500 V DC |
| Short-circuit current rating ISCPV (Additional descriptions) | 2000 A |
| Distance between live and grounded parts (Ambient conditions) | 8 mm |
| Nominal discharge current (8/20) µs (Additional descriptions) | 15 kA |
| Maximum discharge current Imax(8/20) µs (Additional descriptions) | 30 kA |
| Installation location of the disconnect device (Ambient conditions) | Internal |
| Maximum continuous operating voltage UCPV (Additional descriptions) | 750 V DC |
Technical specifications and performance data