Key Specifications
GTIN:4055626540351
Orderkey:1033708
Packing unit:1 pc
Note (General):The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626540351
Orderkey1033708
Packing unit1 pc
Note (General)The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.
Country of originDE (Germany)
(Connection data)(DC-) - G
Custom tariff number85354000
(Ambient conditions)PBT-FR
Altitude (Dimensions)≤ 3000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
(Additional descriptions)≤ 6 kV (at 30 kA)
Color (Ambient conditions)jet black RAL 9005
SPD Type (Connection data)1CA
Depth (Key Commercial Data)65.7 mm
Width (Key Commercial Data)53.4 mm
(Additional technical data)4.5 Nm (25 mm² ... 35 mm²)
EN type (Ambient conditions)T2
Height (Key Commercial Data)89.8 mm
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Nominal voltage (Connection data)1500 V DC
Accessibility (Ambient conditions)Accessible
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (5-500 Hz/2.5 h/XYZ)
Mode of protection (Connection data)(DC+) - (DC-)
Weight per Piece (excluding packing)335.300 g
Housing material (Ambient conditions)PA 6.6-FR
Tightening torque (UL specifications)30 lbf-in.
Horizontal pitch (Key Commercial Data)3 Div.
Mode of protection (Ambient conditions)(L+) - (L-)
Degree of pollution (Ambient conditions)2
Screw thread (Additional technical data)M5
SPD failure behavior (Ambient conditions)OCM (Open-circuit mode)
Installation location (Ambient conditions)Inside
Response time tA (Additional descriptions)≤ 25 ns
Standards/regulations (UL connection data)EN 50539-11 2013
Power distribution system (Connection data)DC PV
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
IEC power supply system (Ambient conditions)DC
IEC test classification (Ambient conditions)PV II
Stripping length (Additional technical data)16 mm
Connection configuration (Ambient conditions)Y configuration
Connection method (Additional technical data)Fork-type cable lug
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Tightening torque (Additional technical data)3 Nm (1,5 mm² ... 16 mm²)
Nominal discharge current In (Connection data)10 kA
Residual current IPE (Additional descriptions)≤ 350 µA DC
Conductor cross section AWG (UL specifications)10 ... 2
Rated load current IL (Additional descriptions)80 A
Residual voltage Ures (Additional descriptions)≤ 5 kV (at In)
Voltage protection rating VPR (Connection data)4 kV
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Short-circuit current rating (SCCR) (Connection data)50 kA
Voltage protection level Up (Additional descriptions)≤ 5 kV
Standby power consumption PC (Additional descriptions)≤ 250 mVA
Conductor cross section AWG (Additional technical data)15 ... 2
Conductor cross section solid (Additional technical data)1.5 mm² ... 35 mm²
Continuous operating current ICPV (Additional descriptions)< 350 µA
Flammability rating according to UL 94 (Ambient conditions)V-0
Maximum continuous operating voltage MCOV (Connection data)1500 V DC
Conductor cross section flexible (Additional technical data)1.5 mm² ... 16 mm²
Short-circuit current rating ISCPV (Additional descriptions)2000 A
Distance between live and grounded parts (Ambient conditions)8 mm
Nominal discharge current (8/20) µs (Additional descriptions)15 kA
Maximum discharge current Imax(8/20) µs (Additional descriptions)30 kA
Total discharge current Itotal(8/20) µs (Additional descriptions)30 kA
Installation location of the disconnect device (Ambient conditions)Internal
Maximum continuous operating voltage UCPV (Additional descriptions)1500 V DC
Nominal discharge current In(8/20) µs (Protective circuit DC voltage side (DC))20 kA (4x (5x In| 120 s) | 30 min))
Maximum discharge current Imax(8/20) µs (Protective circuit DC voltage side (DC))40 kA

Product Description

Surge charger for isolated direct current systems of 1500 V DC and 2 poles, for rail mounting, 3-pole base element, three plug-in protection elements with temperature control, status signaling in each
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents