| Parameter | Value |
|---|---|
| EAN | Four trillion fifty five billion six hundred twenty six million three hundred twenty one thousand one hundred three |
| Key order | Two million nine hundred eight thousand six hundred sixty eight |
| (Overview) | ≤ 2.5 kV (40 kA) |
| Key selling | CL1151 - |
| Packing unit | 36 pcs |
| Country of origin | (Germany) |
| Altitude (Measures) | ≤ 2000 m (amsl (above mean sea level, that is to say, on the level of the sea)) |
| Tariff number tariff | Eighty five million three hundred sixty three thousand ten |
| Minimum order quantity | 36 pcs |
| Unit (Data commercial) | 1 PC |
| Depth (Data commercial) | 55,3 mm |
| Width (Data commercial) | 17.5 mm |
| Height (Data commercial) | 52,4 mm |
| (Environmental conditions) | PV T2 |
| Reaction time tTo (Overview) | ≤ 25 ns |
| Index of protection (Measures) | IP20 |
| Shocks (in service) (Measures) | 60g (Semisinusoide / 11ms / 3x X, And, Z) |
| Color (Environmental conditions) | deep black RAL 9005 |
| Residual voltage Ures (Overview) | ≤ 1,9 kV (In) |
| Unit weight (excluding packaging) | 49,300 g |
| Vibration (in-service) (Measures) | 7.5 g (5-500 Hz / 2.5 h / XYZ) |
| Level of protection Orp (Overview) | ≤ 1,9 kV |
| Type IN (Environmental conditions) | T2 |
| Insulation resistance Riso (Overview) | > 5 GΩ (at 500 V DC) |
| Room temperature (service) (Measures) | -40 °C ... 80 °C |
| Construction (Environmental conditions) | Male |
| Accessibility (Environmental conditions) | Accessible |
| Mounting type (Environmental conditions) | in a base element |
| Absorption of standby power PC (Overview) | ≤ 25 mVA |
| Class test IEC (Environmental conditions) | PV II |
| Constant voltage maximum OrCPV (Overview) | 585 V DC |
| Current of constant service ICPV (Overview) | < 20 µA |
| Material housing (Environmental conditions) | PA 6.6-FR |
| Pollution degree (Environmental conditions) | Two |
| Resistance to short-circuit ISCPV (Overview) | Two thousand |
| Standards/specifications (Specifications UL) | IN 50539-11 2013 |
| Instead of mounting (Environmental conditions) | Interior |
| Transient current nominal (8/20) µs (Overview) | 15 kA |
| Humidity of air permissible (service) (Measures) | 5 % ... 95 % |
| (Protection circuit side voltage (continuous DC)) | (L-) - G |
| Behavior problems in SPD (Environmental conditions) | CMO (Behavior with failure of disconnection) |
| Transient current maximum Imax(8/20) µs (Overview) | 40 kA |
| Ambient temperature (storage / transport) (Measures) | -40 °C ... 80 °C |
| Message surge Protection faulty (Environmental conditions) | optical |
| Type SPD (Protection circuit side voltage (continuous DC)) | 1CA |
| Rated voltage (Protection circuit side voltage (continuous DC)) | 1170 V DC |
| Class of flammability according to UL 94 (Environmental conditions) | V-0 |
| Mounting location of the disconnect device (Environmental conditions) | Internal |
| Tracks of protection (Protection circuit side voltage (continuous DC)) | (L+) - (L-) |
| Power distribution system (Protection circuit side voltage (continuous DC)) | DC PV |
| Transient current nominal In (Protection circuit side voltage (continuous DC)) | 10 kA |
| Constant voltage maximum MCOV (Protection circuit side voltage (continuous DC)) | 1170 V DC |
| Protection nominal voltage VPR (Protection circuit side voltage (continuous DC)) | 3 kV |
| Capacity of short circuit (SCCR) (Protection circuit side voltage (continuous DC)) | 50 kA |
Technical specifications and performance data
Installation and operation guide