| Parameter | Value |
|---|---|
| GTIN | 4046356984225 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2905647 |
| Catalog page | Page 64 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85354000 |
| (Ambient conditions) | (L-) - PE |
| Altitude (Dimensions) | ≤ 6000 m (amsl (above mean sea level)) |
| Type (Ambient conditions) | DIN rail module, one-piece |
| (Additional descriptions) | ≤ 5.4 kV (at 40 kA) |
| Color (Ambient conditions) | traffic grey A RAL 7042 |
| Depth (Key Commercial Data) | 65.5 mm (incl. DIN rail 7.5 mm) |
| Width (Key Commercial Data) | 71.2 mm |
| EN type (Ambient conditions) | T2 |
| Height (Key Commercial Data) | 120 mm |
| Shock (operation) (Dimensions) | 50g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Degree of protection (Dimensions) | IP20 (only when all terminal points are used) |
| Accessibility (Ambient conditions) | Accessible |
| Mounting type (Ambient conditions) | DIN rail: 35 mm |
| Vibration (operation) (Dimensions) | 5g (5 - 500 Hz/2.5 h/X, Y, Z) |
| Weight per Piece (excluding packing) | 383.600 g |
| Housing material (Ambient conditions) | PA 6.6 |
| Horizontal pitch (Key Commercial Data) | 4 Div. |
| Mode of protection (Ambient conditions) | (L+) - (L-) |
| Standards/regulations (Connection data) | EN 50539-11 2013 |
| Degree of pollution (Ambient conditions) | 2 |
| SPD failure behavior (Ambient conditions) | OCM (Open-circuit mode) |
| Installation location (Ambient conditions) | Inside |
| Response time tA (Additional descriptions) | ≤ 25 ns |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 80 °C |
| IEC test classification (Ambient conditions) | PV II |
| Connection configuration (Ambient conditions) | Y configuration |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Residual current IPE (Additional descriptions) | ≤ 55 µA DC |
| Rated load current IL (Additional descriptions) | 50 A |
| Residual voltage Ures (Additional descriptions) | ≤ 4.5 kV (at In) |
| Surge protection fault message (Ambient conditions) | optical |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Insulation resistance Riso (Additional descriptions) | > 5 GΩ (at 500 V DC) |
| Voltage protection level Up (Additional descriptions) | ≤ 4.5 kV |
| Screw thread (Protective circuit DC voltage side (DC)) | M5 |
| Standby power consumption PC (Additional descriptions) | ≤ 85 mVA |
| Stripping length (Protective circuit DC voltage side (DC)) | 16 mm |
| Connection method (Protective circuit DC voltage side (DC)) | Screw connection |
| Continuous operating current ICPV (Additional descriptions) | < 55 µA |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Tightening torque (Protective circuit DC voltage side (DC)) | 3 Nm |
| Short-circuit current rating ISCPV (Additional descriptions) | 2000 A |
| Nominal discharge current (8/20) µs (Additional descriptions) | 20 kA |
| Maximum discharge current Imax(8/20) µs (Additional descriptions) | 40 kA |
| Total discharge current Itotal(8/20) µs (Additional descriptions) | 40 kA |
| Installation location of the disconnect device (Ambient conditions) | Internal |
| Maximum continuous operating voltage UCPV (Additional descriptions) | 1500 V DC |
| Conductor cross section AWG (Protective circuit DC voltage side (DC)) | 14 ... 2 |
| Conductor cross section flexible (Protective circuit DC voltage side (DC)) | 2.5 mm² ... 35 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Protective circuit DC voltage side (DC)) | 10 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Protective circuit DC voltage side (DC)) | 2.5 mm² |
Technical specifications and performance data