Key Specifications
GTIN:4055626063010
Note:Made to Order (non-returnable)
Orderkey:2906293
(General):≤ 3.6 kV (at 40 kA)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626063010
NoteMade to Order (non-returnable)
Orderkey2906293
(General)≤ 3.6 kV (at 40 kA)
Catalog pagePage 41 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363030
(Ambient conditions)(L-) - PE
Altitude (Dimensions)≤ 6000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, one-piece
Color (Ambient conditions)traffic grey A RAL 7042
Response time tA (General)≤ 25 ns
Depth (Key Commercial Data)65.5 mm
Width (Key Commercial Data)71.2 mm
EN type (Ambient conditions)T1 / T2
Height (Key Commercial Data)120 mm
Residual current IPE (General)≤ 45 µA DC
Shock (operation) (Dimensions)50g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)50 A
Residual voltage Ures (General)≤ 2.9 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Accessibility (Ambient conditions)Accessible
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (5 - 500 Hz/2.5 h/X, Y, Z)
Insulation resistance Riso (General)> 5 GΩ (at 500 V DC)
Weight per Piece (excluding packing)417.800 g
Housing material (Ambient conditions)PA 6.6
Voltage protection level Up (General)≤ 2.9 kV
Horizontal pitch (Key Commercial Data)4 Div.
Standby power consumption PC (General)≤ 36 mVA
Mode of protection (Ambient conditions)(L+) - (L-)
Standards/regulations (Connection data)EN 50539-11 2013
Degree of pollution (Ambient conditions)2
SPD failure behavior (Ambient conditions)OCM (Open-circuit mode)
Installation location (Ambient conditions)Inside
Continuous operating current ICPV (General)< 45 µA
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)DC
IEC test classification (Ambient conditions)PV I / II
Short-circuit current rating ISCPV (General)2000 A
Connection configuration (Ambient conditions)Y configuration
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Nominal discharge current (8/20) µs (General)20 kA
Maximum discharge current Imax(8/20) µs (General)40 kA
Total discharge current Itotal(8/20) µs (General)40 kA
Maximum continuous operating voltage UCPV (General)800 V DC
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Total discharge current Itotal(10/350) µs (General)12.5 kA
Screw thread (Protective circuit DC voltage side (DC))M5
Impulse discharge current (10/350) µs, charge (General)3.125 As
Stripping length (Protective circuit DC voltage side (DC))16 mm
Connection method (Protective circuit DC voltage side (DC))Screw connection
Flammability rating according to UL 94 (Ambient conditions)V-0
Tightening torque (Protective circuit DC voltage side (DC))3 Nm
Impulse discharge current (10/350) µs, peak value limp (General)6.25 kA
Impulse discharge current (10/350) µs, specific energy (General)9.77 kJ/Ω
Installation location of the disconnect device (Ambient conditions)Internal
Conductor cross section AWG (Protective circuit DC voltage side (DC))14 ... 2
Conductor cross section flexible (Protective circuit DC voltage side (DC))2.5 mm² ... 35 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Protective circuit DC voltage side (DC))10 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Protective circuit DC voltage side (DC))2.5 mm²

Product Description

Overvoltage/lightning current protection device for isolated and grounded 2-pole photovoltaic 600V DC direct current systems, for rail mounting, temperature-controlled protection elements, status mess
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide