Service time: Monday to Friday 9:00-18:00
UT 6-TMC M 2A - UT 6-TMC M 2A 0916605 PHOENIX CONTACT Thermomagnetic device circuit breaker
In Stock Hot Product

UT 6-TMC M 2A

UT 6-TMC M 2A 0916605 PHOENIX CONTACT Thermomagnetic device circuit breaker

$0.00USD
4138 in stock
Key Specifications
:5 V DC ... 30.8 V DC
Fuse:M1 (normal blow)
Note:No. 235
Type:DIN rail module, one-piece
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
5 V DC ... 30.8 V DC
FuseM1 (normal blow)
NoteNo. 235
TypeDIN rail module, one-piece
Colorgray (RAL 7042)
Depth89.5 mm
Width12.3 mm
Height85.5 mm
Altitude2000 m (acc. to EN 60934)
Fuse typeAutomatic device
Potentials1
Product typeThermomagnetic device circuit breakers
Screw threadM4
Mounting typeDIN rail: 35 mm
Rated voltage240 V AC (50/60 Hz)
Number of rows1
Product familyUT 6-TMC
Tripping levelTrip-free mechanism (positive)
Connection nameAuxiliary contact
No. of channels1
Nominal current2 A
Nominal voltage240 V AC
Open side panelNo
Tripping methodTM (thermomagnetic)
Article revision07
Rated current IN2 A
Stripping length12 mm
Connection methodScrew connection
Cross section AWG24 ... 8 (converted acc. to IEC)
Device resistance330 mΩ
Operating voltage50 V AC ... 264 V AC (48 - 62 Hz)
Power dissipation≤ 1.32 VA
Tightening torque1.5 ... 1.8 Nm
Type of actuationS type
Degree of pollution2
Dielectric strength2000 V
Insulating materialPA66
Number of positions1
Rated surge voltage2.8 kV
Degree of protectionIP40 (Actuation area)
Overvoltage categoryII
Required backup fuse16 A
Temperature derating1.54 A DC (at -30 °C)
Nominal cross section6.00 mm²
Number of connections2
Switching cycles, max.6000 (at 1 x In)
Rated cross section AWG8
Standards/specificationsEN 60934
Insulation resistance Riso> 100 MΩ (main contact)
Conductor cross section AWG24 ... 8
Rated insulation voltage Ui440 V AC
Conductor cross section rigid0.2 mm² ... 10 mm²
Ambient temperature (operation)-30 °C ... 60 °C
Conductor cross section flexible0.2 mm² ... 10 mm²
Flammability rating according to UL 94V-0
Conductor cross section, flexible [AWG]24 ... 8 (converted acc. to IEC)
Rated short-circuit switching capacity Icn200 A (240 V AC)
2 conductors with same cross section, solid0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible0.2 mm² ... 2.5 mm²
Maximum power dissipation for nominal condition≤ 1.32 VA
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 6 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 6 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 6 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 4 mm²

Product Description

Thermomagnetic protection switch, 1 pole, for symmetrical rail mounting
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top