Key Specifications
GTIN:4055626282893
Orderkey:2908205
(General):D1 - 500 A
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626282893
Orderkey2908205
(General)D1 - 500 A
(Drawings)
Catalog pagePage 129 (C-4-2019)
Packing unit1 pc
Depth (Drawings)100 mm (incl. DIN rail 7.5 mm)
UNSPSC 11 (ETIM)39121610
Width (Drawings)6.2 mm +0.1 mm
Country of originDE (Germany)
ETIM 3.0 (eCl@ss)EC000943
ETIM 4.0 (eCl@ss)EC000943
ETIM 5.0 (eCl@ss)EC000943
ETIM 6.0 (eCl@ss)EC000943
ETIM 7.0 (eCl@ss)EC000943
Height (Drawings)105.8 mm
(Connection data)EN 61643-21 2001 + A1:2009 + A2:2013
Diagram (Drawings)
UNSPSC 13.2 (ETIM)39121620
UNSPSC 18.0 (ETIM)39121620
UNSPSC 19.0 (ETIM)39121620
UNSPSC 20.0 (ETIM)39121620
UNSPSC 21.0 (ETIM)39121620
UNSPSC 6.01 (ETIM)30212010
UNSPSC 12.01 (ETIM)39121610
Custom tariff number85363010
Pictogram (Drawings)
UNSPSC 7.0901 (ETIM)39121610
(Ambient conditions)light grey RAL 7035
Altitude (Dimensions)≤ 4000 m (amsl (above mean sea level))
Rated current (General)600 mA (56 °C)
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)traffic grey A RAL 7042
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Nominal voltage UN (General)12 V DC
eCl@ss 4.0 (Classifications)27140201
eCl@ss 4.1 (Classifications)27130801
eCl@ss 5.0 (Classifications)27130801
eCl@ss 5.1 (Classifications)27130801
eCl@ss 6.0 (Classifications)27130800
eCl@ss 7.0 (Classifications)27130807
eCl@ss 8.0 (Classifications)27130807
eCl@ss 9.0 (Classifications)27130807
Resistance per path (General)1.65 Ω ±20 %
Residual current IPE (General)≤ 1 µA
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Mounting type (Ambient conditions)DIN rail: TH 35 - 7.5 mm
Max. required back-up fuse (General)630 mA (FF)
Weight per Piece (excluding packing)40.000 g
Housing material (Ambient conditions)PBT
Input attenuation aE, asym. (General)typ. 0.3 dB (≤ 140 kHz / 150 Ω)
Capacity (line-signalground) (General)typ. 5.2 nF
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Response time tA(line-earth) (General)≤ 100 ns
Maximum continuous voltage UC (General)15 V DC
Pulse reset time (line-earth) (General)≤ 30 ms
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Screw thread (Additional technical data)M3
Impulse durability (line-earth) (General)C1 - 1 kV / 500 A
Standards/specifications (Connection data)IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Stripping length (Additional technical data)8 mm
Connection method (Additional technical data)Screw connection
Operating effective current ICat UC (General)≤ 100 µA
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Response time tA(line-signalground) (General)≤ 1 ns
Tightening torque (Additional technical data)0.5 Nm ... 0.6 Nm
Pulse reset time (line-signalground) (General)≤ 30 ms
Impulse durability (line-signalground) (General)C1 - 1 kV / 500 A
Voltage protection level Up(line-earth) (General)≤ 750 V (C1 - 1 kV/500 A)
Total discharge current Itotal(8/20) µs (General)10 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section AWG (Additional technical data)24 ... 12
Voltage protection level Up(line-signalground) (General)≤ 145 V (C1 - 1 kV/500 A)
Voltage protection level Upstatic (line-earth) (General)≤ 750 V (C1 - 1 kV/500 A)
Conductor cross section solid (Additional technical data)0.2 mm² ... 4 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Additional technical data)0.2 mm² ... 2.5 mm²
Nominal discharge current In(8/20) µs (line-earth) (General)5 kA
Voltage protection level Upstatic (line-signalground) (General)≤ 35 V (C1 - 1 kV/500 A)
Pulse discharge current Iimp(10/350) µs (line-earth) (General)0.5 kA
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system (General)typ. 440 kHz
Nominal discharge current In(8/20) µs (line-signal ground) (General)5 kA
Max. total discharge current Itotal max(8/20) µs (Protective circuit)20 kA (1x)
Pulse discharge current Iimp(10/350) µs (line-signalground) (General)0.5 kA

Product Description

Surge protection, consisting of plug-in protection and base element, with integrated status indication for two signal conductors with common reference potential, e.g. digital INPUT/OUTPUT. Indirect gr
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top