Service time: Monday to Friday 9:00-18:00
TTC-6P-1X2-EX-24DC-UT-I - TTC-6P-1X2-EX-24DC-UT-I 1065312 PHOENIX CONTACT Surge protection, consisting of protective plug and base ele..
In Stock Hot Product

TTC-6P-1X2-EX-24DC-UT-I

TTC-6P-1X2-EX-24DC-UT-I 1065312 PHOENIX CONTACT Surge protection, consisting of protective plug and base ele..

$0.00USD
3601 in stock
Key Specifications
:C2
Note:2018
Type:DIN rail module, two-section, divisible
Color:blue (RAL 5015)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
Note2018
TypeDIN rail module, two-section, divisible
Colorblue (RAL 5015)
Depth100 mm (incl. DIN rail 7.5 mm)
Width6.2 mm +0.1 mm
Height105.8 mm
Altitude≤ 2000 m (amsl)
Product typeSurge protection for MCR technology
Screw threadM3
Mounting typeDIN rail: TH 35 - 7.5 mm
Rated current600 mA (40 °C)
Product familyTERMITRAB complete
Open side panelNo
Article revision10
Housing materialPBT
Pollution degree2
UL, USA / CanadaClass I, Div. 2, Groups A, B, C, D T4A
Connection methodScrew connection
Tightening torque0.5 Nm ... 0.6 Nm
Nominal voltage UN24 V DC
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Insulating materialPBT
Resistance per path1.65 Ω ±20 %
Capacity (Core-Core)typ. 2 nF
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 1 µA
Max. input current Ii400 mA (T4 / -40 °C ... +50 °C)
Max. input voltage Ui30 V DC
Wire pairs per module1
IEC test classificationC1
Standards/specificationsEN 60079-0
Input attenuation aE, sym.typ. 0.3 dB (≤ 250 kHz / 150 Ω)
Max. required back-up fuse630 mA (FF)
Conductor cross section AWG24 ... 12
Max. internal inductance Linegligible
Response time tA(line-line)≤ 1 ns
Insulation voltage to ground> 180 V DC
Maximum inner capacitance Cinegligible
Pulse reset time (line-line)≤ 700 ms
Response time tA(line-earth)≤ 100 ns
Conductor cross section rigid0.2 mm² ... 4 mm²
Maximum continuous voltage UC30 V DC
Pulse reset time (line-earth)≤ 30 ms
Impulse durability (line-line)C1 - 1 kV / 500 A
Surge protection fault messageoptical
Ambient temperature (operation)-40 °C ... 70 °C (with current derating)
Impulse durability (line-earth)C1 - 1 kV / 500 A
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 %
Operating effective current ICat UC≤ 5 µA
Flammability rating according to UL 94V-0
Voltage protection level Up(line-line)≤ 55 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 900 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs10 kA
Voltage protection level Upstatic (line-line)≤ 50 V (C1 - 1 kV / 500 A)
Voltage protection level Upstatic (line-earth)≤ 900 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-line)5 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 940 kHz
Nominal discharge current In(8/20) µs (line-ground)5 kA
Pulse discharge current Iimp(10/350) µs (line-line)0.5 kA
Pulse discharge current Iimp(10/350) µs (line-earth)0.5 kA

Product Description

Surge protection, consisting of plug-in protection and base element, with integrated status indication for a potential-free 2-wire intrinsically safe signal circuit, e.g. 0(4) current loop... 20 mA, s
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top