Service time: Monday to Friday 9:00-18:00
TTC-6-3-HF-F-M-12DC-PT-I - TTC-6-3-HF-F-M-12DC-PT-I 2906778 PHOENIX CONTACT Surge protection with integrated status indicator and knife..
In Stock Hot Product

TTC-6-3-HF-F-M-12DC-PT-I

TTC-6-3-HF-F-M-12DC-PT-I 2906778 PHOENIX CONTACT Surge protection with integrated status indicator and knife..

$0.00USD
4141 in stock
Key Specifications
GTIN:4055626135366
Orderkey:2906778
(General):D1 - 500 A
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626135366
Orderkey2906778
(General)D1 - 500 A
(Drawings)
Catalog pagePage 171 (C-4-2019)
Packing unit1 pc
Depth (Drawings)83.5 mm (incl. DIN rail 7.5 mm)
UNSPSC 11 (ETIM)39121610
Width (Drawings)6.2 mm +0.1 mm
Country of originDE (Germany)
ETIM 3.0 (eCl@ss)EC000943
ETIM 4.0 (eCl@ss)EC000943
ETIM 5.0 (eCl@ss)EC000943
ETIM 6.0 (eCl@ss)EC000943
ETIM 7.0 (eCl@ss)EC000943
Height (Drawings)105.8 mm
(Connection data)EN 61643-21 2001 + A1:2009 + A2:2013
Diagram (Drawings)
UNSPSC 13.2 (ETIM)39121620
UNSPSC 18.0 (ETIM)39121620
UNSPSC 19.0 (ETIM)39121620
UNSPSC 20.0 (ETIM)39121620
UNSPSC 21.0 (ETIM)39121620
UNSPSC 6.01 (ETIM)30212010
UNSPSC 12.01 (ETIM)39121610
Custom tariff number85363010
UNSPSC 7.0901 (ETIM)39121610
Altitude (Dimensions)≤ 4000 m (amsl (above mean sea level))
Rated current (General)600 mA (40 °C)
Type (Ambient conditions)DIN rail module, one-piece
Color (Ambient conditions)traffic grey A RAL 7042
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Nominal voltage UN (General)12 V DC
eCl@ss 4.0 (Classifications)27140201
eCl@ss 4.1 (Classifications)27130801
eCl@ss 5.0 (Classifications)27130801
eCl@ss 5.1 (Classifications)27130801
eCl@ss 6.0 (Classifications)27130800
eCl@ss 7.0 (Classifications)27130807
eCl@ss 8.0 (Classifications)27130807
eCl@ss 9.0 (Classifications)27130807
Resistance per path (General)1.65 Ω ±20 %
Capacity (line-line) (General)typ. 32 pF
Residual current IPE (General)≤ 1 µA
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Mounting type (Ambient conditions)DIN rail: TH 35 - 7.5 mm
Input attenuation aE, sym. (General)typ. 0.3 dB (≤ 8.7 MHz / 150 Ω)
Max. required back-up fuse (General)630 mA (FF)
Weight per Piece (excluding packing)40.000 g
Housing material (Ambient conditions)PBT
Input attenuation aE, asym. (General)typ. 0.3 dB (≤ 10.5 MHz / 150 Ω)
Response time tA(line-line) (General)≤ 1 ns
Capacity (line-signalground) (General)typ. 32 pF
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Pulse reset time (line-line) (General)≤ 30 ms
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Response time tA(line-earth) (General)≤ 100 ns
Maximum continuous voltage UC (General)15 V DC
Pulse reset time (line-earth) (General)≤ 30 ms
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General)C1 - 1 kV / 500 A
Impulse durability (line-earth) (General)C1 - 1 kV / 500 A
Standards/specifications (Connection data)IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Stripping length (Additional technical data)8 mm
Connection method (Additional technical data)Push-in connection
Operating effective current ICat UC (General)≤ 100 µA
Permissible humidity (operation) (Dimensions)5 % ... -40 %
Response time tA(line-signalground) (General)≤ 1 ns
Pulse reset time (line-signalground) (General)≤ 30 ms
Impulse durability (line-signalground) (General)C1 - 1 kV / 500 A
Voltage protection level Up(line-line) (General)≤ 145 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (General)≤ 750 V (C1 - 1 kV/500 A)
Total discharge current Itotal(8/20) µs (General)10 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section AWG (Additional technical data)24 ... 12
Voltage protection level Upstatic (line-line) (General)≤ 40 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-signalground) (General)≤ 80 V (C1 - 1 kV/500 A)
Voltage protection level Upstatic (line-earth) (General)≤ 40 V (C1 - 1 kV/500 A)
Conductor cross section solid (Additional technical data)0.2 mm² ... 4 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Additional technical data)0.2 mm² ... 2.5 mm²
Nominal discharge current In(8/20) µs (line-line) (General)5 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)typ. 60 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)5 kA
Voltage protection level Upstatic (line-signalground) (General)≤ 750 V (C1 - 1 kV/500 A)
Pulse discharge current Iimp(10/350) µs (line-earth) (General)0.5 kA
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system (General)typ. 60 MHz
Nominal discharge current In(8/20) µs (line-signal ground) (General)5 kA
Max. total discharge current Itotal max(8/20) µs (Protective circuit)20 kA (1x)
Pulse discharge current Iimp(10/350) µs (line-signalground) (General)0.5 kA

Product Description

Surge protection with integrated status indication and blade separation for three signal conductors with common reference potential. For high-frequency applications and telecommunication interfaces wi
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top