Service time: Monday to Friday 9:00-18:00
TT-ST-M-2/2-24DC - TT-ST-M-2/2-24DC 2858917 PHOENIX CONTACT Surge protection device
In Stock Hot Product

TT-ST-M-2/2-24DC

TT-ST-M-2/2-24DC 2858917 PHOENIX CONTACT Surge protection device

$0.00USD
4979 in stock
Key Specifications
GTIN:4017918938017
Note:Made to Order (non-returnable)
Orderkey:2858917
(General):C3 - 100 A
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918938017
NoteMade to Order (non-returnable)
Orderkey2858917
(General)C3 - 100 A
Catalog pagePage 96 (C-6-2015)
Packing unit10 pc
Country of originDE (Germany)
(Connection data)EN 61643-21/A1 2009
Custom tariff number85363030
(Ambient conditions)IEC 60664-1
Altitude (Dimensions)max. 2000 m
Rated current (General)300 mA (45°C)
Type (Ambient conditions)Double-level terminal block with disconnect knife
Color (Ambient conditions)black
Depth (Key Commercial Data)65.1 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)6.2 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)100 mm
Nominal voltage UN (General)24 V DC
Residual current IPE (General)≤ 20 µA
Resistance in series (General)9.4 Ω ±10 %
Capacity (line-earth) (General)2 nF
VDE requirement class (General)C1
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Mounting type (Ambient conditions)DIN rail: 35 mm
Max. required back-up fuse (General)315 mA
Weight per Piece (excluding packing)28.790 g
Housing material (Ambient conditions)PA 6.6
Input attenuation aE, asym. (General)typ. 0.6 dB (500 kHz/50 Ω)
Stripping length (Protective circuit)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Protective circuit)Spring-cage connection
Response time tA(line-earth) (General)≤ 1 ns
Standby power consumption PC (General)≤ 1.86 VA
Maximum continuous voltage UC (General)30 V DC
Degree of pollution (Ambient conditions)2
Direction of action (Ambient conditions)Line-Earth Ground
Number of positions (Ambient conditions)2
Surge protection fault message (General)none
Connection method IN (Protective circuit)Spring-cage
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Overvoltage category (Ambient conditions)III
Connection method OUT (Protective circuit)Spring-cage
Standards/specifications (Connection data)IEC 61643-21/A1 2008
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Residual voltage at In(line-earth) (General)≤ 40 V
Operating effective current ICat UC (General)≤ 10 µA (per path)
Conductor cross section AWG (Protective circuit)24 ... 14
Voltage protection level Up(line-earth) (General)≤ 80 V (C2 - 10 kV / 5 kA)
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General)1 kA (per path)
Total discharge current Itotal(8/20) µs (General)10 kA
Total discharge current Itotal(10/350) µs (General)2 kA
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Flammability rating according to UL 94 (Ambient conditions)V-2
Nominal discharge current In(8/20) µs (line-earth) (General)5 kA
Nominal pulse current Ian (10/1000) µs (line-earth) (General)100 A
Residual voltage with Ian (10/1000) µs (line-earth) (General)≤ 45 V
Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm system (General)typ. 3 MHz
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 40 V
Cut-off frequency fg (3 dB), asym. (PE) in 150 Ohm system (General)typ. 1 MHz
Cut-off frequency fg (3 dB), asym. (PE) in 600 Ohm system (General)typ. 250 kHz
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 40 V
Standards for cearances and creepage distances (Ambient conditions)EN 60664-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)5 kA

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents