| Parameter | Value |
|---|---|
| Ean | 4017918247393 |
| Sell key | CLA121 - |
| Order key | 0915496 |
| (General) | 1500 V AC (Pole to Pole) |
| (Measurement) | IP20 (Connection Zone) |
| Packaging unit | 2 pcs |
| Country of origin | DE (Germany) |
| Tariff rate number | 85362010 |
| Fuse Type (General) | Automatic fuse |
| Depth (Electrical data) | 96 mm |
| Width (Electrical data) | 37.5 mm |
| Colour (Commercial data) | black |
| Height (Electrical data) | 82.5 mm |
| Rated Current IN (General) | 3 A |
| Isolation (Commercial data) | PA66 |
| REACh SVHC (Connection data) | Lead 7439-92-1 |
| Degree of pollution (General) | 2 |
| Dielectric Strength (General) | 3000 V AC (Drive Range) |
| Protection Index (Measurement) | IP30 (Drive Range) |
| Number of poles (Commercial data) | 3 |
| Number of floors (Commercial data) | 2 |
| Type of mounting (Commercial data) | Symmetrical rail: 35 mm |
| Insulating material group (General) | Ii |
| Insulation Resistance RISO (General) | > 100 MΩ (500 VDC) |
| Male Gauge (Environmental conditions) | A3 |
| Weight per unit (excluding packaging) | 197,200 g |
| Number of connections (Commercial data) | 4 |
| Screw thread (Environmental conditions) | M3 |
| Standard-compliant connection (General) | IEC / EN |
| Category of sobretensiones_GRP (General) | Ii |
| Dimensioning Transient Voltage (General) | 2.5 kV |
| Connection type (Environmental conditions) | Screw connection |
| Ambient Temperature (Service) (Measurement) | -30 °C ... 60 °C |
| Maximum state change periodicities (General) | 10000 (In 1 x In, inductive) |
| Short-circuit breaking capacity Ik (General) | 5000 A () |
| Category of sobretensiones_GRP (Commercial data) | Ii |
| Max. tightening torque. (Environmental conditions) | 0.8 Nm |
| Min. tightening torque. (Environmental conditions) | 0.6 Nm |
| Length to be de-insulated (Environmental conditions) | 12 mm |
| Conductor section AWG max. (Environmental conditions) | 10 |
| Conductor section AWG min. (Environmental conditions) | 24 |
| Max. rigid conductor section (Environmental conditions) | 6 mm² |
| Rigid conductor section min. (Environmental conditions) | 0.2 mm² |
| Short-Circuit Assigned Breakdown Capacity ICn (General) | 400 A |
| Combustibility class according to UL 94 (Commercial data) | V-2 |
| Flexible conductor section min. (Environmental conditions) | 0.2 mm² |
| Max. flexible conductor section (Environmental conditions) | 4 mm² |
| 2 conductors with the same cross-section, rigid max. (Environmental conditions) | 0.75 mm² |
| 2 conductors with the same cross-section, rigid min. (Environmental conditions) | 0.2 mm² |
| 2 conductors with the same cross-section, flexible max. (Environmental conditions) | 0.75 mm² |
| 2 conductors with the same cross-section, flexible min. (Environmental conditions) | 0.2 mm² |
| Flexible conductor section with tip, with min plastic sleeve. (Environmental conditions) | 0.25 mm² |
| Flexible conductor section with ferrule, with plastic sleeve max. (Environmental conditions) | 2.5 mm² |
| Flexible conductor section with toe cap, without min plastic sleeve. (Environmental conditions) | 0.25 mm² |
| Flexible conductor section with toe cap, without plastic sleeve max. (Environmental conditions) | 4 mm² |
| 2 conductors with the same cross-section, flexible with HAE without plastic sleeve max. (Environmental conditions) | 1 mm² |
| 2 conductors with the same cross-section, flexible with HAE, without min plastic sleeve. (Environmental conditions) | 0.25 mm² |
| 2 conductors with the same cross-section, flexible with TWIN-HAE with plastic sleeve max. (Environmental conditions) | 2.5 mm² |
| 2 conductors with the same cross-section, flexible with TWIN-AEH, with min plastic sleeve. (Environmental conditions) | 0.5 mm² |
Technical specifications and performance data
Installation and operation guide