Service time: Monday to Friday 9:00-18:00
TAE-TRAB FM-NFN-AP - TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device
In Stock Hot Product

TAE-TRAB FM-NFN-AP

TAE-TRAB FM-NFN-AP 2749628 PHOENIX CONTACT Surge protection device

$0.00USD
4051 in stock
Key Specifications
GTIN:4017918108199
Orderkey:2749628
(General):D1 - 2.5 kA
Catalog page:Page 165 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918108199
Orderkey2749628
(General)D1 - 2.5 kA
Catalog pagePage 165 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363010
(Ambient conditions)IEC 60664-1
Rated current (General)450 mA (≤ 40°C)
Type (Ambient conditions)Socket for surface mounting
Color (Ambient conditions)cream white
Depth (Key Commercial Data)80 mm
Width (Key Commercial Data)65 mm
Height (Key Commercial Data)27 mm
Nominal voltage UN (General)60 V DC
Capacity (line-line) (General)typ. 200 pF (f = 1 MHz / VR = 0 V)
Residual current IPE (General)≤ 6 µA
Resistance in series (General)2.2 Ω 10 %
Capacity (line-earth) (General)typ. 15 pF (f = 1 MHz / VR = 0 V)
VDE requirement class (General)B2
Degree of protection (Dimensions)IP20
IEC test classification (General)B2
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)Surface/Wall mounting
Stripping length (Connection data)6 mm
Connection method (Connection data)Screw terminal block
(Connection, equipotential bonding)IEC 61643-21 2000
Input attenuation aE, sym. (General)0.3 dB (≤ 1 MHz / 150 Ω)
Weight per Piece (excluding packing)79.600 g
Housing material (Ambient conditions)ABS
Input attenuation aE, asym. (General)0.3 dB (≤ 400 kHz / 600 Ω)
Response time tA(line-line) (General)≤ 1 ns
Stripping length (Protective circuit)6 mm
Connection method (Protective circuit)Screw connection & TAE 6
Response time tA(line-earth) (General)≤ 100 ns
Tightening torque (Protective circuit)0.5 Nm
Maximum continuous voltage UC (General)185 V DC
Direction of action (Ambient conditions)Line-Line & Line-Earth Ground
Impulse durability (line-line) (General)C2 - 10 kV/5 kA
Surge protection fault message (General)none
Tightening torque, min (Connection data)0.5 Nm
Connection method IN (Protective circuit)Screw terminal blocks
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Connection method OUT (Protective circuit)3x TAE-NFN
Connection technology (Protective circuit)Screw connection
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
Operating effective current ICat UC (General)≤ 10 µA
Short-circuit current self-quenching (General)150 mA
Conductor cross section AWG (Protective circuit)26 ... 16
For country-specific use in (Ambient conditions)D
Voltage protection level Up(line-line) (General)≤ 250 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth) (General)≤ 500 V (C2 - 10 kV / 5 kA)
Conductor cross section AWG max. (Connection data)16
Conductor cross section AWG min. (Connection data)26
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Total discharge current Itotal(8/20) µs (General)10 kA
Conductor cross section solid max. (Connection data)1.5 mm²
Conductor cross section solid min. (Connection data)0.14 mm²
Total discharge current Itotal(10/350) µs (General)5 kA
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Conductor cross section flexible max. (Connection data)1.5 mm²
Conductor cross section flexible min. (Connection data)0.14 mm²
Standards/regulations (Connection, equipotential bonding)IEC 61643-21
Alternating current carrying capacity (line-earth) (General)5 A - 1 s
Nominal discharge current In(8/20) µs (line-line) (General)5 kA
Nominal pulse current Ian (10/700) µs (line-line) (General)150 A
Standards/specifications (Connection, equipotential bonding)DIN EN 61643-21 2002
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)typ. 8 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm system (General)typ. 2 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)5 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General)100 A
Nominal pulse current Ian (10/700) µs (line-earth) (General)150 A
Nominal pulse current Ian (10/1000) µs (line-earth) (General)100 A
Output voltage limitation at 1 kV/µs (line-line) spike (General)≤ 250 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 450 V
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 250 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General)5 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 450 V
Standards for cearances and creepage distances (Ambient conditions)VDE 0110-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)5 kA

Product Description

Spray-protected TAE (NFN) connection box with surge protection for analogue and digital telecommunication interfaces (VDSL up to 50 MBit/s, short distances (< 300 m) up to 100 MBit/s)
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide