Service time: Monday to Friday 9:00-18:00
S-PT-1X2-24DC - S-PT-1X2-24DC 2880668 PHOENIX CONTACT Surge protection device
In Stock Hot Product

S-PT-1X2-24DC

S-PT-1X2-24DC 2880668 PHOENIX CONTACT Surge protection device

$0.00USD
3248 in stock
Key Specifications
GTIN:4046356049009
Note:Made to Order (non-returnable)
Orderkey:2880668
(General):D1 - 1 kA
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356049009
NoteMade to Order (non-returnable)
Orderkey2880668
(General)D1 - 1 kA
Catalog pagePage 101 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363010
(Ambient conditions)VDE 0110-1
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Rated current (General)450 mA (55 °C)
Type (Ambient conditions)Screw-in module
Color (Ambient conditions)silver
Depth (Key Commercial Data)137 mm
Width (Key Commercial Data)33.5 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)33.5 mm
Nominal voltage UN (General)24 V DC
Residual current IPE (General)≤ 2 µA
Resistance in series (General)2.2 Ω ±10 %
Degree of protection (Dimensions)IP67
IEC test classification (General)C1
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)direct screw connection
Input attenuation aE, sym. (General)typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
Max. required back-up fuse (General)500 mA (T)
Weight per Piece (excluding packing)352.520 g
Housing material (Ambient conditions)Zinc die-cast, surface bronzed and nickel-plated
Response time tA(line-line) (General)≤ 1 ns
Stripping length (Protective circuit)6 mm
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Connection method (Protective circuit)Screw connection
Response time tA(line-earth) (General)≤ 100 ns
Tightening torque (Protective circuit)0.6 Nm
Maximum continuous voltage UC (General)40 V DC
Direction of action (Ambient conditions)Line-Line & Line-Earth Ground
Impulse durability (line-line) (General)C2 - 10 kV/5 kA
Number of positions (Ambient conditions)3
Surge protection fault message (General)none
Connection method IN (Protective circuit)Screw terminal blocks
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Response time tA (shield-earth) (General)≤ 100 ns
Connection method OUT (Protective circuit)Connection line
Connection technology (Protective circuit)Screw connection
Standards/specifications (Connection data)IEC 61643-21 2002
Impulse durability (shield-earth) (General)C2 - 10 kV / 5 kA
Residual voltage at In(line-line) (General)≤ 55 V
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Operating effective current ICat UC (General)≤ 10 µA
Conductor cross section AWG (Protective circuit)26 ... 16
Voltage protection level Up(line-line) (General)≤ 80 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth) (General)≤ 450 V (C2 - 10 kV / 5 kA)
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
Pulse discharge current Iimp(10/350) µs (General)1 kA
Total discharge current Itotal(8/20) µs (General)20 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Total discharge current Itotal(10/350) µs (General)2 kA
Voltage protection level Up(shield-ground) (General)≤ 600 V (C2 - 10 kV / 5 kA)
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Voltage protection level Upstatic (line-line) (General)≤ 50 V (C2 - 10 kV / 5 kA)
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General)typ. 6 MHz
Nominal discharge current In(8/20) µs (line-line) (General)10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)typ. 2 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)10 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-line) (General)23 A
Residual voltage with Ian (10/1000) µs (line-line) (General)≤ 65 V
Nominal pulse current Ian (10/1000) µs (line-earth) (General)100 A
Nominal discharge current In(8/20) µs (shield-earth) (General)10 kA (optional)
Nominal pulse current Ian (10/1000) µs (Shield-Earth) (General)100 A
Output voltage limitation at 1 kV/µs (line-line) spike (General)≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 450 V (Direct grounding)
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 55 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General)10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 450 V (Direct grounding)
Standards for cearances and creepage distances (Ambient conditions)IEC 60664-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)10 kA (per path)
Output voltage limitation at 1 kV/µs (shield-earth) spike (General)≤ 600 V (optional)
Max. discharge current Imax(8/20) µs maximum (shield-earth) (General)10 kA

Product Description

Overvoltage protection. in IP67 screw-on module for measuring probes, direct mounting via ext. thread. M20 x 1.5, cable gland for signal line, circ. of Protec. two-tiered. Suitable for HART.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top