Key Specifications
:C2
Note:2002
Type:Screw-in module
Color:Steel/stainless steel color
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
Note2002
TypeScrew-in module
ColorSteel/stainless steel color
Depth148 mm
Width33.5 mm
Height33.5 mm
Altitude≤ 2000 m (amsl)
Product typeSurge protection for MCR technology
Screw threadM3
Mounting typedirect screw connection
Rated current450 mA (55 °C)
Product familySURGETRAB
Open side panelNo
Article revision12
Housing materialZinc die-cast, surface bronzed and nickel-plated
Pollution degree2
Connection methodScrew connection
Tightening torque0.6 Nm
Nominal voltage UN24 V DC
Notes on operationWhen the bridge is disconnected, the shield connection is indirectly connected to the housing or reference potential.
Dimensional drawing
Direction of actionLine-Line & Line-Earth Ground
Number of positions3
Resistance per path2.2 Ω ±10 %
Degree of protectionIP67
Overvoltage categoryIII
Residual current IPE≤ 2 µA
Standards/regulationsIEC 60664-1 / VDE 0110-1
Wire pairs per module1
IEC test classificationC1
Standards/specificationsIEC 61643-21
Input attenuation aE, sym.typ. 0.5 dB (≤ 1.5 MHz / 50 Ω)
Max. required back-up fuse500 mA (T)
Conductor cross section AWG26 ... 16
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Maximum continuous voltage UC40 V DC
Impulse durability (line-line)C2 - 10 kV / 5 kA
Surge protection fault messagenone
Ambient temperature (operation)-40 °C ... 85 °C
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Response time tA (shield-ground)≤ 100 ns
Impulse durability (shield-ground)C2 - 10 kV/5 kA
Operating effective current ICat UC≤ 10 µA
Voltage protection level Up(line-line)≤ 80 V (C2 - 10 kV / 5 kA)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 450 V (C2 - 10 kV / 5 kA)
Pulse discharge current Iimp(10/350) µs1 kA
Total discharge current Itotal(8/20) µs20 kA
Voltage protection level Up(shield-ground)≤ 600 V (C2 - 10 kV / 5 kA)
Residual voltage at In(conductor-conductor)≤ 55 V
Total discharge current Itotal(10/350) µs2 kA
Voltage protection level Upstatic (line-line)≤ 50 V (C2 - 10 kV / 5 kA)
Nominal discharge current In(8/20) µs (line-line)10 kA
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 6 MHz
Nominal pulse current Ian (10/1000) µs (line-line)23 A
Residual voltage with Ian (10/1000) µs (line-line)≤ 65 V
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 2 MHz
Nominal discharge current In(8/20) µs (line-ground)10 kA (per path)
Nominal pulse current Ian (10/1000) µs (line-earth)100 A
Nominal discharge current In(8/20) µs (shield-ground)10 kA (optional)
Nominal pulse current Ian (10/1000) µs (shield-ground)100 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 450 V (Direct grounding)
Output voltage limitation at 1 kV/µs (line-line) static≤ 55 V
Max. discharge current Imax(8/20) µs maximum (line-line)10 kA
Output voltage limitation at 1 kV/µs (line-earth) static≤ 450 V (Direct grounding)
Max. discharge current Imax(8/20) µs maximum (line-earth)10 kA (per path)
Output voltage limitation at 1 kV/µs (shield-ground) spike≤ 600 V (optional)
Discharge surge current Imax(8/20) µs maximum (shield-ground)10 kA

Product Description

Overvoltage protection. in IP67 screw-on module for measuring probes, direct mounting via 3/4'' NPT ext. thread, cable gland for signal line, circ. of Protec. two-tiered. Suitable for HART.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top