Service time: Monday to Friday 9:00-18:00
PTCB E1 24DC/1-8A NO2 - PTCB E1 24DC/1-8A NO2 1388391 PHOENIX CONTACT 1-channel electronic equipment protection switch to protect co..
In Stock Hot Product

PTCB E1 24DC/1-8A NO2

PTCB E1 24DC/1-8A NO2 1388391 PHOENIX CONTACT 1-channel electronic equipment protection switch to protect co..

$60.61USD
204 in stock
Key Specifications
:Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures
EMC:B
Fuse:electronic
Note:EN 50121-3-2: Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock – Apparatus
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures
EMCB
Fuseelectronic
NoteEN 50121-3-2: Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock – Apparatus
TypeDIN rail module, one-piece
Depth55.6 mm (incl. DIN rail 7.5 mm)
Width6.2 mm
Height105.8 mm
Altitude≤ 3000 m up to 52 °C (amsl)
HumidityB
MaterialPBT
EnclosureA
VibrationB
Efficiency> 99 %
TemperatureA
Product typeDevice circuit breakers
Voltage drop0.13 V (at 8 A)
Humidity test96 h, 95 % RH, 40 °C
Mounting typeDIN rail: 35 mm
Rated voltage24 V DC
Shutdown time≤ 10 ms (for short circuit > 2.0 x IN)
IdentificationUL/C-UL Listed UL 508
Product familyPTCB
Channel LED offoff (Channel switched off)
Channel LED redlit (Channel switched off, over- or undervoltage active)
Connection nameRemote indication circuit
Tripping methodE (electronic)
Pollution degree2
Protection classIII
Rated current IN24 A DC (Total current input)
Stripping length8 mm
Channel LED greenlit (Channel switched on)
Connection methodPush-in connection
Cross section AWG(converted acc. to IEC)
Fail-safe element15 A DC
Operating current100 mA DC
Operating voltage18 V DC ... 30 V DC
Power dissipationtyp. 0.3 W (No-load operation)
Shock (operation)30g (IEC 60068-2-27, Test Ea)
Channel LED yellowlit (Channel switched on, channel load > 80% )
Switching functionN/O contact
Dielectric strengthmax. 35 V DC (Load circuit)
Dimensional drawing
Feedback resistancemax. 35 V DC
Number of positions1
Rated surge voltage0.5 kV
Degree of protectionIP20
Max. capacitive load25000 µF (Depending on the current setting and the short-circuit current available)
Required backup fuseOnly required if Imaxof the power supply > the short-circuit switching capacity. Integrated failsafe element.
Temperature derating21 A (Total current at 60°C)
Measuring tolerance I± 15 %
Vibration (operation)10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Overvoltage switch-off≥ 30.5 V DC (active)
Undervoltage switch-off≤ 17.8 V DC (active)
Standards/specificationsEN 61000-6-2
Closed circuit current I0typ. 12 mA
MTBF (IEC 61709, SN 29500)25641025 h (at 25 °C with 21 % load)
Module initialization time< 0.55 s
Conductor cross section AWG24 ... 12
Rated current (pre-adjusted)4 A
Conductor cross section rigid0.2 mm² ... 4 mm²
Ambient temperature (operation)-30 °C ... 60 °C
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Short-circuit switching capacity300 A
Flammability rating according to UL 94V-0
Ambient temperature (storage/transport)-40 °C ... 70 °C
Waiting time after switch off of a channel5 s (at overload / short circuit)
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 2.5 mm²

Product Description

1-channel, electronic circuit breaker for protecting loads at 24 V DC against overload and short circuit. Easy potential distribution with components from the CLIPLINE complete terminal block system.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top