Service time: Monday to Friday 9:00-18:00
PTCB E1 24DC/1-8A NO - PTCB E1 24DC/1-8A NO 2908262 PHOENIX CONTACT Electronic device circuit breaker
In Stock Hot Product

PTCB E1 24DC/1-8A NO

PTCB E1 24DC/1-8A NO 2908262 PHOENIX CONTACT Electronic device circuit breaker

$0.00USD
3210 in stock
Key Specifications
GTIN:4055626323763
Orderkey:2908262
(General):≤ 29.5 V DC (inactive)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626323763
Orderkey2908262
(General)≤ 29.5 V DC (inactive)
Packing unit1 pc
(Dimensions)59.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
Country of originDE (Germany)
(Connection data)UL 2367
Fuse type (General)electronic
Custom tariff number85363010
Efficiency (General)> 99 %
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Voltage drop (General)0.13 V (at 8 A)
Rated voltage (General)24 V DC
Tripping method (General)E (electronic)
Type (Ambient conditions)DIN rail module, one-piece
Color (Ambient conditions)traffic grey A RAL 7042
Humidity test (Dimensions)96 h, 95 % RH, 40 °C
Rated current IN (General)24 A DC (Total current input)
Connection name (Signaling)Main circuit OUT
Depth (Key Commercial Data)55.6 mm
Fail-safe element (General)15 A DC
Operating voltage (General)18 V DC ... 30 V DC
Power dissipation (General)typ. 0.3 W (No-load operation)
Width (Key Commercial Data)6.2 mm
(Remote indication contact)flashing quickly (Channel switched off, external voltage at the output, possible installation error)
Height (Key Commercial Data)105.8 mm
Stripping length (Signaling)10 mm
Connection method (Signaling)Push-in connection
Dielectric strength (General)max. 35 V DC (Load circuit)
Feedback resistance (General)max. 35 V DC
Rated surge voltage (General)0.5 kV
Required backup fuse (General)not required, integrated failsafe element
Shock (operation) (Dimensions)30g (IEC 60068-2-27, Test Ea)
Temperature derating (General)21 A (Total current at 60°C)
Measuring tolerance I (General)± 15 %
Connection name (Electrical data)Remote indication circuit
Degree of protection (Dimensions)IP20
Mounting type (Ambient conditions)DIN rail: 35 mm
Stripping length (Electrical data)10 mm
Vibration (operation) (Dimensions)10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
Closed circuit current I0 (General)typ. 12 mA
MTBF (IEC 61709, SN 29500) (General)25641025 h (at 25°C with 21% load)
Module initialization time (General)1 s
Shutdown time load circuit (General)≤ 10 ms (for short circuit > 2.0 x IN)
Switching function (Electrical data)N/O contact
Weight per Piece (excluding packing)27.640 g
Protection class (Ambient conditions)III
DC operating current (Electrical data)100 mA DC
DC operating voltage (Electrical data)0 V DC ... 30 V DC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Conductor cross section AWG (Signaling)24 ... 12
Number of positions (Ambient conditions)1
Conductor cross section solid (Signaling)0.2 mm² ... 4 mm²
Standards/specifications (Connection data)EN 61000-6-2
Channel LED off (Remote indication contact)off (Channel switched off)
Channel LED red (Remote indication contact)lit (Channel switched off, over- or undervoltage active)
Max. capacitive load load circuit (General)35000 µF (Depending on the current setting and the short-circuit current available)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Undervoltage shutdown load circuit (General)≤ 17.8 V DC (active)
Channel LED green (Remote indication contact)lit (Channel switched on)
Conductor cross section AWG (Electrical data)24 ... 14
Surge voltage shutdown load circuit (General)≥ 30.5 V DC (active)
Channel LED yellow (Remote indication contact)lit (Channel switched on, channel load > 80% )
Conductor cross section solid (Electrical data)0.2 mm² ... 4 mm²
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 70 °C
Waiting time after switch off of a channel (General)5 s (at overload / short circuit)
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section, flexible, with ferrule, with plastic sleeve (Signaling)0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve (Signaling)0.2 mm² ... 2.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical data)0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve (Electrical data)0.2 mm² ... 2.5 mm²

Product Description

1-channel electronic switch for equipment protection to protect consumers in 24 V DC in case of overload and short circuit. Easy potential distribution with the components of the CLIPLINE complete ter
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top