| Parameter | Value |
|---|---|
| Repeated strong short circuits can reduce the melting integral of the integrated safety fuse. | |
| EMC | to |
| Fuse | electronic |
| Depth | 55.6 mm (With 7.5 mm rail) |
| Width | 6.2 mm |
| Yield | > 98.5% |
| Height | 105.8 mm |
| Marked | UL/C-UL Listed UL 508 |
| tension | < 5V DC (Low State) |
| Altitude | ≤ 3000 m up to 52 °C (amsl) |
| Humidity | B |
| Material | PBT |
| Enclosure | to |
| Shot Type | E (electronic) |
| Vibration | B |
| Observation | Connection for the signal line tested according to EN 61000-4-4 with 1 kV; If applicable, protective measures should be provided on the client's side |
| Temperature | to |
| Construction | Rail-mounted, one-piece module |
| Product Type | Appliance Protection Switches, Electronic |
| Pulse Length | ≥ 50 ms (High) |
| Voltage drop | 0.28 V (with 0.5 A) |
| Humidity check | 96 h, 95% RH, 40 °C |
| Output current | max. 0.015 A (Short Circuit Resistant) |
| Output voltage | 24 V DC (Error) |
| Product Family | PTCB |
| Connection type | Push-in connection |
| LED Channel Off | Off (Channel Off) |
| Nominal voltage | 24 V DC |
| Number of poles | 1 |
| Red LED Channel | Ignition (Channel Off, Overvoltage, or Active Undervoltage) |
| Dimension Scheme | |
| Dissipated Power | Typ. 0.1W (no load) |
| Protection Index | IP20 |
| Rated Current IN | 15 A DC (Total Input Current) |
| Rules/Provisions | EN 61000-6-2 |
| Surge Disconnect | ≥ 30.5 V DC (active) |
| Type of mounting | Symmetrical rail: 35 mm |
| Fail Safe Element | 4 A DC |
| Green LED Channel | On (Channel Connected) |
| Operating voltage | 10 V DC ... 30 V DC |
| Pre-fuse required | It is only necessary if IMaxof the power supply is > the ability to short circuit. Built-in safety feature. |
| Current absorption | Typ. 0.4 mA (with 24 V DC) |
| Disconnection Time | ≤ 600 ms |
| Kind of protection | Iii |
| Number of channels | 1 |
| Resting Current I0 | Typ. 3.8 mA |
| Yellow LED Channel | flashes (Programming Mode On) |
| Degree of pollution | 2 |
| Dielectric Strength | max. 35 V DC (Charging circuit) |
| Input Voltage Range | 7 V DC ... 30 V DC (Downside Reset) |
| Crashes (in service) | 30g (IEC 60068-2-27, Ea test) |
| Max. capacitive load | 5.7 mF (Depending on current setting and available short-circuit current) |
| Temperature derating | 15 A (Total current at 60°C) |
| AWG Conductor Section | 24 ... 12 |
| Rated current (preset) | 0.5 A |
| Vibration (in service) | 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; according to IEC 60068-2-6, Fc test) |
| Active Current Limiting | Typ. 1.1 x IN |
| Measurement Tolerance I | ± 7% |
| Rigid conductor section | 0.2 mm² ... 2.5 mm² |
| Undervoltage disconnect | ≤ 9.2 V DC (active) |
| Recirculation Resistance | max. 35 V DC |
| Length to be de-insulated | 8 mm |
| Flexible conductor section | 0.2 mm² ... 2.5 mm² |
| MTBF (IEC 61709, SN 29500) | 27129679 h (at 25°C at 21% load) |
| Module Initialization Time | 40 ms |
| Ambient Temperature (Service) | -30 °C ... 60 °C |
| Dimensioning Transient Voltage | 0.5 kV |
| Short-circuit breakdown capability | 300 A |
| Flammability class according to UL 94 | V-0 |
| Timeout after disconnecting a channel | 5 sec (in overload/short circuit) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Flexible conductor section with toe cap, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Flexible conductor section with toe cap, without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Technical specifications and performance data
Installation and operation guide