Key Specifications
:C2
Note:Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
NoteRemote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth77.5 mm (incl. DIN rail 7.5 mm)
Width17.7 mm
Height91 mm
Altitude≤ 4000 m (amsl)
Product typeSurge protection for information technology
Screw threadM3
Mounting typeDIN rail: 35 mm
Rated current600 mA (40 °C)
Product familyPLUGTRAB IQ
Open side panelNo
Article revision05
Horizontal pitch1 Div.
Housing materialPA 6.6
Pollution degree2
Connection methodScrew connection
Tightening torque0.5 Nm
Nominal voltage UN12 V DC
Transmission speed90 Mpbs
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path1.2 Ω ±5 %
Capacity (Core-Core)typ. 30 pF
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 10 µA (per path)
Standards/regulationsIEC 60664-1
IEC test classificationC1
Standards/specificationsIEC 61643-21
Input attenuation aE, sym.typ. 0.3 dB (≤ 10 MHz/150 Ω)
Max. required back-up fuse600 mA (FF)
Conductor cross section AWG24 ... 12
Input attenuation aE, asym.typ. 0.3 dB (≤ 10 MHz/150 Ω)
Response time tA(line-line)≤ 1 ns
Capacity (line-signalground)typ. 30 pF
Pulse reset time (line-line)≤ 15 ms
Response time tA(line-earth)≤ 100 ns
Conductor cross section rigid0.2 mm² ... 4 mm²
Maximum continuous voltage UC15 V DC
Pulse reset time (line-earth)≤ 15 ms
Impulse durability (line-line)C1 - 1 kV / 500 A
Surge protection fault messageOptical, multi-stage
Ambient temperature (operation)-40 °C ... 70 °C
Impulse durability (line-earth)C1 - 1 kV / 500 A
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 %
Operating effective current ICat UC≤ 100 µA (per path)
Response time tA(line-signalground)≤ 1 ns
Pulse reset time (line-signalground)≤ 15 ms
Flammability rating according to UL 94V-0
Impulse durability (line-signalground)C1 - 1 kV / 500 A
Voltage protection level Up(line-line)≤ 100 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 730 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs20 kA
Voltage protection level Upstatic (line-line)≤ 55 V (C1 - 1 kV / 500 A)
Voltage protection level Up(line-signalground)≤ 100 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-line)10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 60 MHz
Nominal discharge current In(8/20) µs (line-ground)10 kA
Voltage protection level Upstatic (line-signalground)≤ 55 V (C1 - 1 kV / 500 A)
Pulse discharge current Iimp(10/350) µs (line-earth)2.5 kA
Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω systemtyp. 60 MHz

Product Description

Surge protection, consisting of plug-in protection and base element, with multi-level diagnostic and status indication integrated into a module for five signal conductors. For HF applications and tele
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top