Service time: Monday to Friday 9:00-18:00
PT-IQ-2X2-EX-24DC-UT - PT-IQ-2X2-EX-24DC-UT 2801513 PHOENIX CONTACT Surge protection device
In Stock Hot Product

PT-IQ-2X2-EX-24DC-UT

PT-IQ-2X2-EX-24DC-UT 2801513 PHOENIX CONTACT Surge protection device

$0.00USD
3414 in stock
Key Specifications
GTIN:4046356801232
Orderkey:2801513
(General):D1 - 2 kA
Catalog page:Page 129 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356801232
Orderkey2801513
(General)D1 - 2 kA
Catalog pagePage 129 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363010
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Rated current (General)350 mA
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)black
Depth (Key Commercial Data)77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.7 mm
(Remote indication contact)EN 61000-6-3 A1:2011
(Standards and Regulations)-40 °C ... 70 °C (T4)
Height (Key Commercial Data)91.1 mm
Nominal voltage UN (General)24 V DC
Residual current IPE (General)≤ 100 nA (per system)
Resistance in series (General)1.2 Ω ±5 %
Capacity (line-earth) (General)typ. 2 nF
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)DIN rail: 35 mm
Connection method (Connection data)DIN rail NS35
Input attenuation aE, sym. (General)typ. 0.3 dB (≤ 300 kHz / 150 Ω)
Max. required back-up fuse (General)350 mA (F)
Weight per Piece (excluding packing)123.000 g
Housing material (Ambient conditions)PA 6.6
Response time tA(line-line) (General)≤ 1 ns
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw connection
Horizontal pitch (Key Commercial Data)1 Div.
Pulse reset time (line-line) (General)≤ 30 ms
Response time tA(line-earth) (General)≤ 100 ns
Tightening torque (Protective circuit)0.5 Nm
Maximum continuous voltage UC (General)30 V DC
Pulse reset time (line-earth) (General)≤ 30 ms
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General)C1 - 1 kV/500 A
Surge protection fault message (General)Optical, multi-stage
Impulse durability (line-earth) (General)C2 - 10 kA
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Operating effective current ICat UC (General)≤ 5 µA (per system)
max. input power Pi (Standards and Regulations)1.2 W
Conductor cross section AWG (Protective circuit)24 ... 12
Voltage protection level Up(line-line) (General)≤ 60 V (C1 - 1 kV/500 A)
Max. input current Ii (Standards and Regulations)350 mA
Max. input voltage Ui (Standards and Regulations)30 V DC
Voltage protection level Up(line-earth) (General)≤ 1.3 kV (C2 - 10 kV / 5 kA)
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Total discharge current Itotal(8/20) µs (General)20 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standards/specifications (Remote indication contact)EN 61643-21 A2:2013
Standards/specifications (Standards and Regulations)EN 60079-0 2012
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Switching function (Connection, equipotential bonding)via DIN rail connector
Max. internal inductance Li (Standards and Regulations)negligible
Insulation voltage to ground (Standards and Regulations)> 500 V AC
Maximum inner capacitance Ci (Standards and Regulations)negligible
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 50 °C (T6)
Flammability rating according to UL 94 (Ambient conditions)V-0
Nominal discharge current In(8/20) µs (line-line) (General)10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)typ. 1.1 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (General)2 kA

Product Description

Surge protection, consisting of plug-in protection and base element, with multi-level diagnostic and status indication integrated into the module for two potential-free 2-wire Ex-i signal circuits.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top