Service time: Monday to Friday 9:00-18:00
PT-IQ-2X1-12DC-PT - PT-IQ-2X1-12DC-PT 2801245 PHOENIX CONTACT Surge protection device
In Stock Hot Product

PT-IQ-2X1-12DC-PT

PT-IQ-2X1-12DC-PT 2801245 PHOENIX CONTACT Surge protection device

$0.00USD
3077 in stock
Key Specifications
:C2
Note:Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type:DIN rail module, two-section, divisible
Depth:77.5 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
NoteRemote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
TypeDIN rail module, two-section, divisible
Depth77.5 mm (incl. DIN rail 7.5 mm)
Width17.7 mm
Height109.3 mm
Altitude≤ 4000 m (amsl)
Product typeSurge protection for MCR technology
Mounting typeDIN rail: 35 mm
Rated current1000 mA (40 °C)
Product familyPLUGTRAB IQ
Horizontal pitch1 Div.
Housing materialPA 6.6
Pollution degree2
Connection methodPush-in connection
Nominal voltage UN12 V DC
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path1.2 Ω ±5 %
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 1 mA (per path)
IEC test classificationC1
Standards/specificationsIEC 61643-21
Max. required back-up fuse1 A (FF)
Conductor cross section AWG24 ... 12
Input attenuation aE, asym.typ. 0.3 dB (≤ 130 kHz/150 Ω)
Capacity (line-signalground)typ. 4 nF
Response time tA(line-earth)≤ 1 ns
Conductor cross section rigid0.2 mm² ... 4 mm²
Maximum continuous voltage UC15 V DC
Pulse reset time (line-earth)≤ 15 ms
Surge protection fault messageOptical, multi-stage
Ambient temperature (operation)-40 °C ... 70 °C
Impulse durability (line-earth)C1 - 1 kV / 500 A
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Operating effective current ICat UC≤ 1 mA (per path)
Flammability rating according to UL 94V-0
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 90 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs20 kA
Voltage protection level Upstatic (line-earth)≤ 45 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-ground)10 kA
Pulse discharge current Iimp(10/350) µs (line-earth)2.5 kA
Cut-off frequency fg (3 dB), asym. (PE) in 150 Ω systemtyp. 600 kHz

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide