Service time: Monday to Friday 9:00-18:00
PT-IQ-1X2+F-5DC-PT - PT-IQ-1X2+F-5DC-PT 2801252 PHOENIX CONTACT Surge protection device
In Stock Hot Product

PT-IQ-1X2+F-5DC-PT

PT-IQ-1X2+F-5DC-PT 2801252 PHOENIX CONTACT Surge protection device

$0.00USD
3580 in stock
Key Specifications
GTIN:4046356766357
Note:Made to Order (non-returnable)
Orderkey:2801252
Catalog page:Page 97 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356766357
NoteMade to Order (non-returnable)
Orderkey2801252
Catalog pagePage 97 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363030
Altitude (Dimensions)≤ 4000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
(Additional descriptions)C3 - 100 A
Color (Ambient conditions)jet black RAL 9005
Depth (Key Commercial Data)77.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.7 mm
Height (Key Commercial Data)109.3 mm
Degree of protection (Dimensions)IP20
Mounting type (Ambient conditions)DIN rail: 35 mm
Connection method (Connection data)DIN rail NS35
(Connection, equipotential bonding)EN 61000-6-2 2005
Weight per Piece (excluding packing)137.300 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)10 mm
Connection method (Protective circuit)Push-in connection
Horizontal pitch (Key Commercial Data)1 Div.
Rated current (Additional descriptions)1000 mA (40 °C)
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C
Nominal voltage UN (Additional descriptions)5 V DC
Capacity (line-line) (Additional descriptions)typ. 7.5 nF
Residual current IPE (Additional descriptions)≤ 1 µA
Resistance in series (Additional descriptions)1.2 Ω ±5 %
Conductor cross section AWG (Protective circuit)24 ... 12
IEC test classification (Additional descriptions)C1
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Input attenuation aE, sym. (Additional descriptions)typ. 0.3 dB (≤ 40 kHz/150 Ω)
Max. required back-up fuse (Additional descriptions)1 A (FF)
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Response time tA(line-line) (Additional descriptions)≤ 1 ns
Pulse reset time (line-line) (Additional descriptions)≤ 10 ms
Response time tA(line-earth) (Additional descriptions)≤ 100 ns
Maximum continuous voltage UC (Additional descriptions)6 V DC
Pulse reset time (line-earth) (Additional descriptions)≤ 10 ms
Impulse durability (line-line) (Additional descriptions)C1 - 1 kV/500 A
Surge protection fault message (Additional descriptions)Optical, multi-stage
Impulse durability (line-earth) (Additional descriptions)C1 - 1 kV/500 A
Flammability rating according to UL 94 (Ambient conditions)V-0
Standards/specifications (Connection, equipotential bonding)IEC 61643-21 2000 + A1:2008 + A2:2012
Operating effective current ICat UC (Additional descriptions)≤ 2 mA (in the signal circuit)
Pulse reset time (line-signalground) (Additional descriptions)≤ 10 ms
Response time tA (line-signalground) (Additional descriptions)≤ 100 ns
Impulse durability (line-signalground) (Additional descriptions)C1 - 1 kV/500 A
Voltage protection level Up(line-line) (Additional descriptions)≤ 85 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (Additional descriptions)≤ 900 V (C1 - 1 kV/500 A)
Total discharge current Itotal(8/20) µs (Additional descriptions)20 kA
Voltage protection level Upstatic (line-line) (Additional descriptions)≤ 26 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-signalground) (Additional descriptions)≤ 600 V (C1 - 1 kV/500 A)
Voltage protection level Upstatic (line-earth) (Additional descriptions)≤ 130 V (C2 - 10 kV / 5 kA)
Nominal discharge current In(8/20) µs (line-line) (Additional descriptions)10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (Additional descriptions)typ. 300 kHz
Nominal discharge current In(8/20) µs (line-earth) (Additional descriptions)10 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (Additional descriptions)2.5 kA
Voltage protection level Upstatic (line-signalground) (Additional descriptions)≤ 60 V (C2 - 10 kV / 5 kA)
Nominal discharge current In(8/20) µs (core-signal ground) (Additional descriptions)10 kA

Product Description

Surge protection consisting of plug-in protection and base element, with integrated multi-level status indication in the module, for a floating 2-wire signal circuit. Indirect grounding by gas dischar
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top