Service time: Monday to Friday 9:00-18:00
PT-IQ-1X2-24DC-UT - PT-IQ-1X2-24DC-UT 2800976 PHOENIX CONTACT Surge protection device
In Stock Hot Product

PT-IQ-1X2-24DC-UT

PT-IQ-1X2-24DC-UT 2800976 PHOENIX CONTACT Surge protection device

$0.00USD
3819 in stock
Key Specifications
:C2
Note:Remote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
Type:DIN rail module, two-section, divisible
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
NoteRemote signaling as well as the power supply of the DIN rail connector are established by snapping the module into place on the DIN rail connector.
TypeDIN rail module, two-section, divisible
Colorblack (RAL 9005)
Depth77.5 mm (incl. DIN rail 7.5 mm)
Width17.7 mm
Height91.1 mm
Altitude≤ 4000 m (amsl)
Product typeSurge protection for MCR technology
Screw threadM3
Mounting typeDIN rail: 35 mm
Rated current1000 mA (40 °C)
Product familyPLUGTRAB IQ
Open side panelNo
Article revision08
Horizontal pitch1 Div.
Housing materialPA 6.6
Pollution degree2
Connection methodScrew connection
Tightening torque0.5 Nm
Nominal voltage UN24 V DC
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Resistance per path1.2 Ω ±5 %
Capacity (Core-Core)typ. 2 nF
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 2 µA (per signal circuit)
Wire pairs per module1
IEC test classificationC1
Standards/specificationsIEC 61643-21
Input attenuation aE, sym.typ. 0.3 dB (≤ 270 kHz/150 Ω)
Max. required back-up fuse1 A (FF)
Conductor cross section AWG24 ... 12
Response time tA(line-line)≤ 1 ns
Pulse reset time (line-line)≤ 4000 ms
Response time tA(line-earth)≤ 100 ns
Conductor cross section rigid0.2 mm² ... 4 mm²
Maximum continuous voltage UC30 V DC
Pulse reset time (line-earth)≤ 2600 ms
Impulse durability (line-line)C1 - 1 kV / 500 A
Surge protection fault messageOptical, multi-stage
Ambient temperature (operation)-40 °C ... 70 °C
Impulse durability (line-earth)C1 - 1 kV / 500 A
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 %
Operating effective current ICat UC≤ 1 mA (in the signal circuit)
Flammability rating according to UL 94V-0
Voltage protection level Up(line-line)≤ 80 V (C1 - 1 kV / 500 A)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 600 V (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs20 kA
Voltage protection level Upstatic (line-line)≤ 65 V (C1 - 1 kV / 500 A)
Nominal discharge current In(8/20) µs (line-line)10 kA
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 1.1 MHz
Nominal discharge current In(8/20) µs (line-ground)10 kA
Pulse discharge current Iimp(10/350) µs (line-earth)2.5 kA

Product Description

Surge protection, consisting of plug-in protection and base element, with multi-level status indication integrated into the module, for a 2-wire signal circuit driven free of earth potential, suitable
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top