Key Specifications
GTIN:4017918480646
Orderkey:2838775
(General):D1 - 2.5 kA
Catalog page:Page 147 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918480646
Orderkey2838775
(General)D1 - 2.5 kA
Catalog pagePage 147 (C-4-2017)
Packing unit10 pc
Country of originDE (Germany)
(Connection data)IEC 61643-21 A2:2012
Custom tariff number85363010
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Rated current (General)450 mA (45°C)
Type (Ambient conditions)Male
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 500 ns
Depth (Key Commercial Data)52 mm
Width (Key Commercial Data)17.7 mm
Height (Key Commercial Data)45 mm
Nominal voltage UN (General)12 V DC
Capacity (line-line) (General)typ. 30 pF
Residual current IPE (General)≤ 5 µA (with PT 2X2-BE)
Resistance in series (General)2.2 Ω ±10 %
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)on base element
Input attenuation aE, sym. (General)typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Max. required back-up fuse (General)500 mA (T)
Weight per Piece (excluding packing)25.600 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw connection (in connection with the base element)
Horizontal pitch (Key Commercial Data)1 Div.
Tightening torque (Protective circuit)0.8 Nm
Maximum continuous voltage UC (General)14 V DC
Degree of pollution (Ambient conditions)2
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General)C2 - 10 kV/5 kA
Number of positions (Ambient conditions)5
Surge protection fault message (General)none
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Overvoltage category (Ambient conditions)III
Standards/specifications (Connection data)EN 61643-21 A2:2013
Complete module depth (Key Commercial Data)65.5 mm
Complete module width (Key Commercial Data)17.7 mm
Residual voltage at In(line-line) (General)≤ 25 V
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Complete module height (Key Commercial Data)90 mm
Residual voltage at In(line-earth) (General)≤ 40 V (with PT 2X2-BE)
Operating effective current ICat UC (General)≤ 5 µA
Conductor cross section AWG (Protective circuit)24 ... 12
Voltage protection level Up(line-line) (General)≤ 80 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (General)≤ 85 V (C1 - 1 kV / 500 A with PT 2X2-BE)
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General)2.5 kA
Total discharge current Itotal(8/20) µs (General)20 kA
Residual voltage at In(line-signalground) (General)≤ 25 V (with PT 2X2-BE)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Voltage protection level Upstatic (line-line) (General)≤ 25 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-signalground) (General)≤ 50 V (C3 - 25 A with PT 2X2-BE)
Voltage protection level Upstatic (line-earth) (General)≤ 45 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
Flammability rating according to UL 94 (Ambient conditions)V-0
Nominal discharge current In(8/20) µs (line-line) (General)10 kA
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General)typ. 60 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)20 kA (in total)
Nominal pulse current Ian (10/1000) µs (line-line) (General)67 A
Residual voltage with Ian (10/1000) µs (line-line) (General)≤ 25 V
Voltage protection level Upstatic (line-signalground) (General)≤ 25 V (C2 - 10 kV / 5 kA with PT 2X2-BE)
Output voltage limitation at 1 kV/µs (line-line) spike (General)≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 55 V (with PT 2X2-BE)
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 25 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General)10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 25 V (with PT 2X2-BE)
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)20 kA (in total)
Residual voltage with Ian (10/1000) µs (line-signalground) (General)≤ 25 V
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions)From SW rev. 1.10

Product Description

PT plug-in protection with HF (high frequency) protection circuit for 4 signal conductors. Rated voltage: 12 V DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide