Service time: Monday to Friday 9:00-18:00
PT 4-EX(I)-24DC-ST - PT 4-EX(I)-24DC-ST 2839253 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 4-EX(I)-24DC-ST

PT 4-EX(I)-24DC-ST 2839253 PHOENIX CONTACT Surge protection plug

$0.00USD
3865 in stock
Key Specifications
:C2
ATEX: II 1G Ex ia IIC T4...T6 Ga
Note:A2:2013
Type:Male
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
ATEX II 1G Ex ia IIC T4...T6 Ga
NoteA2:2013
TypeMale
Colorblue (RAL 5015)
Depth51.7 mm
IECExEx ia IIC T4...T6 Ga
Width17.7 mm
Height44.8 mm
Altitude≤ 2000 m (amsl)
Product typeSurge protection for MCR technology
Screw threadM3
Mounting typeon base element
Rated current500 mA (40 °C)
Product familyPLUGTRAB PT
Open side panelNo
Article revision26
Horizontal pitch1 Div.
Housing materialPA 6.6
Pollution degree2
Connection methodScrew connection (in connection with the base element)
Tightening torque0.5 Nm
Nominal voltage UN24 V DC
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Number of positions4
Resistance per path0 Ω
max. input power Pi850.00 mW (T4 / ≤ 80°C)
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 4 µA
Complete module depth65.5 mm
Complete module width17.7 mm
Max. input current Ii500 mA (T4 / ≤ 80°C)
Max. input voltage Ui30 V DC
Complete module height90 mm
IEC test classificationC1
Standards/specificationsEN 61643-21
Input attenuation aE, sym.typ. 0.1 dB (≤ 1 MHz / 50 Ω)
Max. required back-up fuse500 mA (T)
Conductor cross section AWG24 ... 12
Max. internal inductance Li1 µH
Response time tA(line-line)≤ 1 ns
Maximum inner capacitance Ci1.1 nF
Response time tA(line-earth)≤ 100 ns
Conductor cross section rigid0.2 mm² ... 4 mm²
Maximum continuous voltage UC30 V DC
Impulse durability (line-line)C1 - 0.5 kV / 250 A
Surge protection fault messagenone
Ambient temperature (operation)-40 °C ... 80 °C (T4)
Impulse durability (line-earth)C1 - 1 kV / 500 A
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Maximum inner time factor (Ri/Li)≤ 10 µs
Operating effective current ICat UC≤ 5 µA
Flammability rating according to UL 94V-0
Voltage protection level Up(line-line)≤ 60 V (C1 - 500 V / 250 A)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 1 kV (C1 - 1 kV / 500 A)
Total discharge current Itotal(8/20) µs20 kA
Residual voltage at In(conductor-conductor)≤ 70 V
Total discharge current Itotal(10/350) µs2 kA
Alternating current carrying capacity (line-earth)5 A - 1 s
Nominal discharge current In(8/20) µs (line-line)308 A
Cut-off frequency fg (3 dB), sym. in 50 Ω systemtyp. 7 MHz
Nominal pulse current Ian (10/1000) µs (line-line)59 A
Residual voltage with Ian (10/1000) µs (line-line)≤ 65 V
Cut-off frequency fg (3 dB), sym. in 150 Ω systemtyp. 2.5 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ω systemtyp. 600 kHz
Nominal discharge current In(8/20) µs (line-ground)10 kA
Pulse discharge current Iimp(10/350) µs (line-earth)1 kA
Output voltage limitation at 1 kV/µs (line-line) spike≤ 45 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 1 kV
Output voltage limitation at 1 kV/µs (line-line) static≤ 45 V
Max. discharge current Imax(8/20) µs maximum (line-line)308 A
Output voltage limitation at 1 kV/µs (line-earth) static≤ 1 kV
Max. discharge current Imax(8/20) µs maximum (line-earth)20 kA (in total)
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.00

Product Description

PT plug-in protection protection circuit for a 4-conductor Ex i signal circuit with no earth potential. Rated voltage: 24 V DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top