Service time: Monday to Friday 9:00-18:00
PT 3-PB-ST - PT 3-PB-ST 2858030 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 3-PB-ST

PT 3-PB-ST 2858030 PHOENIX CONTACT Surge protection plug

$0.00USD
3200 in stock
Key Specifications
GTIN:4017918878030
Orderkey:2858030
(General):D1 - 2.5 kA
Catalog page:Page 154 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918878030
Orderkey2858030
(General)D1 - 2.5 kA
Catalog pagePage 154 (C-4-2017)
Packing unit10 pc
Country of originDE (Germany)
Custom tariff number85363090
(Ambient conditions)IEC 60664-1
Altitude (Dimensions)max. 2000 m
Rated current (General)450 mA (45°C)
Type (Ambient conditions)Male
Color (Ambient conditions)black
Depth (Key Commercial Data)52 mm
Width (Key Commercial Data)17.7 mm
Height (Key Commercial Data)45 mm
Nominal voltage UN (General)5 V DC
Capacity (line-line) (General)typ. 30 pF
Residual current IPE (General)≤ 300 µA (with PT 1X2-BE)
Resistance in series (General)2.2 Ω ±10 % (7-8/11-12)
VDE requirement class (General)C1
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)on base element
Stripping length (Connection data)8 mm
(Connection, equipotential bonding)IEC 61643-21/A1 2008
Input attenuation aE, sym. (General)typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Max. required back-up fuse (General)500 mA (T)
Weight per Piece (excluding packing)20.530 g
Housing material (Ambient conditions)PA
Response time tA(line-line) (General)≤ 500 ns
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw connection (in connection with the base element)
Horizontal pitch (Key Commercial Data)1 Div.
Response time tA(line-earth) (General)≤ 500 ns
Tightening torque (Protective circuit)0.8 Nm
Maximum continuous voltage UC (General)5.2 V DC
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General)C2 - 10 kV/5 kA
Number of positions (Ambient conditions)2
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Complete module depth (Key Commercial Data)65.5 mm
Complete module width (Key Commercial Data)17.7 mm
Residual voltage at In(line-line) (General)≤ 15 V
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Complete module height (Key Commercial Data)90 mm
Residual voltage at In(line-earth) (General)≤ 30 V (with PT 1X2-BE)
Operating effective current ICat UC (General)≤ 300 µA
Response time tA (line-signalground) (General)≤ 500 ns
Conductor cross section AWG (Protective circuit)24 ... 12
Voltage protection level Up(line-line) (General)≤ 70 V (C1 - 1 kV/500 A)
Voltage protection level Up(line-earth) (General)≤ 80 V (C1 - 1 kV/500 A)
Conductor cross section AWG max. (Connection data)12
Conductor cross section AWG min. (Connection data)24
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Pulse discharge current Iimp(10/350) µs (General)2.5 kA
Total discharge current Itotal(8/20) µs (General)20 kA
Residual voltage at In(line-signalground) (General)≤ 15 V (with PT 1X2-BE)
Conductor cross section solid max. (Connection data)4 mm²
Conductor cross section solid min. (Connection data)0.2 mm²
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Conductor cross section flexible max. (Connection data)2.5 mm²
Conductor cross section flexible min. (Connection data)0.2 mm²
Voltage protection level Up(line-signalground) (General)≤ 45 V (C3 - 25 A)
Flammability rating according to UL 94 (Ambient conditions)V-0
Nominal discharge current In(8/20) µs (line-line) (General)10 kA
Standards/specifications (Connection, equipotential bonding)EN 61643-21/A1 2009
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General)typ. 60 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)10 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General)90 A
Residual voltage with Ian (10/1000) µs (line-line) (General)≤ 15 V
Output voltage limitation at 1 kV/µs (line-line) spike (General)≤ 55 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 55 V (with PT 1X2-BE)
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 15 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General)10 kA
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 15 V
Standards for cearances and creepage distances (Ambient conditions)DIN EN 61664-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)10 kA
Residual voltage with Ian (10/1000) µs (line-signalground) (General)≤ 15 V
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions)From SW rev. 1.10

Product Description

Plug-in surge protection for base element, coarse and fine transverse voltage protection for two signal conductors without earth potential in information technology, coarse protection against longitud
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty