| Parameter | Value |
|---|---|
| GTIN | 4017918182861 |
| Orderkey | 2838225 |
| (General) | Ex ia IIIC T135 °C...T85 °C Da |
| Catalog page | Page 132 (C-4-2017) |
| Packing unit | 10 pc |
| ATEX (General) | II 1G Ex ia IIC T4...T6 Ga |
| IECEx (General) | Ex ia IIC T4...T6 Ga |
| Country of origin | DE (Germany) |
| (Connection data) | IEC 60079-26 2006 |
| Custom tariff number | 85363010 |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Rated current (General) | 325 mA (40 °C) |
| (Conformity / approvals) | No hazardous substances above threshold values |
| Type (Ambient conditions) | Male |
| Color (Ambient conditions) | sky blue RAL 5015 |
| Depth (Key Commercial Data) | 51.7 mm |
| Width (Key Commercial Data) | 17.5 mm |
| (Standards and Regulations) | -40 °C ... 40 °C (T6) |
| Height (Key Commercial Data) | 44.8 mm |
| Nominal voltage UN (General) | 24 V DC |
| Residual current IPE (General) | ≤ 4 µA |
| Resistance in series (General) | 2.2 Ω ±10 % |
| Degree of protection (Dimensions) | IP20 |
| IEC test classification (General) | C1 |
| Screw thread (Protective circuit) | M3 |
| Mounting type (Ambient conditions) | on base element |
| China RoHS (Conformity / approvals) | Environmentally friendly use period: unlimited = EFUP-e |
| Input attenuation aE, sym. (General) | typ. 0.5 dB (≤ 900 kHz / 50 Ω) |
| Max. required back-up fuse (General) | 315 mA (T) |
| Weight per Piece (excluding packing) | 21.090 g |
| Housing material (Ambient conditions) | PA 6.6 |
| Response time tA(line-line) (General) | ≤ 1 ns |
| Stripping length (Protective circuit) | 8 mm |
| Connection method (Protective circuit) | Screw connection (in connection with the base element) |
| Horizontal pitch (Key Commercial Data) | 1 Div. |
| Response time tA(line-earth) (General) | ≤ 100 ns |
| Tightening torque (Protective circuit) | 0.5 Nm |
| Maximum continuous voltage UC (General) | 30 V DC |
| Direction of action (Ambient conditions) | Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
| Impulse durability (line-line) (General) | C1 - 0.5 kV / 250 A |
| Number of positions (Ambient conditions) | 4 |
| Surge protection fault message (General) | none |
| Impulse durability (line-earth) (General) | C1 - 1 kV/500 A |
| Standards/specifications (Connection data) | EN 61643-21 A2:2013 |
| Complete module depth (Key Commercial Data) | 65.5 mm |
| Complete module width (Key Commercial Data) | 17.7 mm |
| Residual voltage at In(line-line) (General) | ≤ 45 V |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 85 °C |
| Complete module height (Key Commercial Data) | 90 mm |
| Operating effective current ICat UC (General) | ≤ 5 µA |
| max. input power Pi (Standards and Regulations) | 3 W |
| Conductor cross section AWG (Protective circuit) | 24 ... 12 |
| Voltage protection level Up(line-line) (General) | ≤ 45 V (C1 - 0.5 kV / 250 A) |
| Max. input current Ii (Standards and Regulations) | 325 mA (T4 / ≤ 80°C) |
| Max. input voltage Ui (Standards and Regulations) | 30 V DC |
| Voltage protection level Up(line-earth) (General) | ≤ 1 kV (C1 - 1 kV/500 A) |
| Conductor cross section solid (Protective circuit) | 0.2 mm² ... 4 mm² |
| Total discharge current Itotal(8/20) µs (General) | 20 kA |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Total discharge current Itotal(10/350) µs (General) | 2 kA |
| Conductor cross section flexible (Protective circuit) | 0.2 mm² ... 2.5 mm² |
| Max. internal inductance Li (Standards and Regulations) | 1 µH |
| Maximum inner capacitance Ci (Standards and Regulations) | 1.3 nF |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 80 °C (T4) |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Alternating current carrying capacity (line-earth) (General) | 10 A - 1 s |
| Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General) | typ. 4.5 MHz |
| Nominal discharge current In(8/20) µs (line-line) (General) | 10 kA |
| Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General) | typ. 1.6 MHz |
| Cut-off frequency fg (3 dB), sym. in 600 Ohm system (General) | typ. 400 kHz |
| Maximum inner time factor (Ri/Li) (Standards and Regulations) | ≤ 0.2 µs |
| Nominal discharge current In(8/20) µs (line-earth) (General) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) (General) | 30 A |
| Residual voltage with Ian (10/1000) µs (line-line) (General) | ≤ 50 V |
| Pulse discharge current Iimp(10/350) µs (line-line) (General) | 1 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) (General) | 2 kA (in total) |
| Output voltage limitation at 1 kV/µs (line-line) spike (General) | ≤ 45 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike (General) | ≤ 1 kV |
| Output voltage limitation at 1 kV/µs (line-line) static (General) | ≤ 45 V |
| Max. discharge current Imax(8/20) µs maximum (line-line) (General) | 10 kA |
| Output voltage limitation at 1 kV/µs (line-earth) static (General) | ≤ 1 kV |
| Max. discharge current Imax(8/20) µs maximum (line-earth) (General) | 20 kA (in total) |
| Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) | From SW rev. 1.00 |