Service time: Monday to Friday 9:00-18:00
PT 2X2-FF-ST - PT 2X2-FF-ST 2800755 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 2X2-FF-ST

PT 2X2-FF-ST 2800755 PHOENIX CONTACT Surge protection plug

$0.00USD
4241 in stock
Key Specifications
:C2
Note:2009
Type:Male
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
Note2009
TypeMale
Colorblack (RAL 9005)
Depth52 mm
Width17.7 mm
Height45 mm
Altitude≤ 2000 m (amsl)
Product typeSurge protection for information technology
Mounting typeon base element
Rated current1.6 A
Product familyPLUGTRAB PT
Open side panelNo
Article revision09
Horizontal pitch1 Div.
Housing materialPA
Pollution degree2
Connection methodScrew connection (in connection with the base element)
Nominal voltage UN32 V DC
Dimensional drawing
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Number of positions5
Resistance per path≤ 1 Ω
Degree of protectionIP20
Overvoltage categoryIII
Residual current IPE≤ 5 µA (with PT 4-BE)
Complete module depth65.5 mm
Complete module width17.7 mm
Standards/regulationsDIN VDE 0110-1 / IEC 60664-1
VDE requirement classC1
Wire pairs per module2
Complete module height90 mm
IEC test classificationC1
Standards/specificationsEN 61643-21/A1
Response time tA(line-line)≤ 1 ns
Response time tA(line-earth)≤ 100 ns
Maximum continuous voltage UC36 V DC
Impulse durability (line-line)C3 - 25 A
Surge protection fault messagenone
Ambient temperature (operation)-40 °C ... 85 °C
Impulse durability (line-earth)C1 - 1 kV / 500 A
Operating effective current ICat UC≤ 5 µA
Flammability rating according to UL 94V0
Voltage protection level Up(line-line)≤ 75 V (C3 - 25 A)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Voltage protection level Up(line-earth)≤ 1.3 kV (C1 - 1.5 kV)
Pulse discharge current Iimp(10/350) µs1 kA
Nominal discharge current In(8/20) µs (line-line)100 A
Nominal pulse current Ian (10/1000) µs (line-line)23 A
Nominal discharge current In(8/20) µs (line-ground)10 kA
Output voltage limitation at 1 kV/µs (line-line) spike≤ 75 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 1.3 kV (with PT 4-BE)
Output voltage limitation at 1 kV/µs (line-line) static≤ 75 V
Max. discharge current Imax(8/20) µs maximum (line-line)100 A
Max. discharge current Imax(8/20) µs maximum (line-earth)10 kA

Product Description

PLUGTRAB, Plug-in Surge Protection for Foundation Fieldbus
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top