Service time: Monday to Friday 9:00-18:00
PT 2X1VA-230AC-ST - PT 2X1VA-230AC-ST 2839198 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 2X1VA-230AC-ST

PT 2X1VA-230AC-ST 2839198 PHOENIX CONTACT Surge protection plug

$0.00USD
4650 in stock
Key Specifications
GTIN:4017918182854
Orderkey:2839198
(General):PT -BE/ FM 2839282
Catalog page:Page 114 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918182854
Orderkey2839198
(General)PT -BE/ FM 2839282
Catalog pagePage 114 (C-4-2017)
Packing unit10 pc
Note (General)Technical data is valid in association with the following specified base elements:
Country of originDE (Germany)
(Connection data)EN 61643-21 2001 + A1:2009 + A2:2013
Custom tariff number85363010
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)Male
(Additional descriptions)D1 - 500 A
Color (Ambient conditions)jet black RAL 9005
Depth (Key Commercial Data)51.7 mm
Width (Key Commercial Data)17.5 mm
Height (Key Commercial Data)44.8 mm
Degree of protection (Dimensions)IP20
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)on base element
Weight per Piece (excluding packing)24.230 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw connection (in connection with the base element)
Horizontal pitch (Key Commercial Data)1 Div.
Tightening torque (Protective circuit)0.5 Nm
Rated current (Additional descriptions)26 A AC (30 °C)
Direction of action (Ambient conditions)Line-Line & Line-Earth Ground
Standards/specifications (Connection data)IEC 61643 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Complete module depth (Key Commercial Data)65.5 mm
Complete module width (Key Commercial Data)17.7 mm
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Complete module height (Key Commercial Data)90 mm
Nominal voltage UN (Additional descriptions)230 V AC (50/60 Hz)
Residual current IPE (Additional descriptions)≤ 3 mA AC
Capacity (line-earth) (Additional descriptions)typ. 1 nF
Conductor cross section AWG (Protective circuit)24 ... 12
IEC test classification (Additional descriptions)C1
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Max. required back-up fuse (Additional descriptions)25 A AC (gL/gG)
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Input attenuation aE, asym. (Additional descriptions)typ. 0.3 dB (≤ 650 kHz / 150 Ω)
Response time tA(line-earth) (Additional descriptions)≤ 25 ns
Maximum continuous voltage UC (Additional descriptions)275 V DC
Surge protection fault message (Additional descriptions)none
Impulse durability (line-earth) (Additional descriptions)C1 - 1,4 kV / 0,7 kA
Flammability rating according to UL 94 (Ambient conditions)V-0
Operating effective current ICat UC (Additional descriptions)≤ 1.5 mA AC
Voltage protection level Up(line-earth) (Additional descriptions)≤ 750 V (C1 - 1.4 kV / 0.7 kA)
Pulse discharge current Iimp(10/350) µs (Additional descriptions)500 A
Total discharge current Itotal(8/20) µs (Additional descriptions)5 kA
Nominal discharge current In(8/20) µs (line-earth) (Additional descriptions)2.5 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (Additional descriptions)≤ 650 V
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions)From SW rev. 1.00
Output voltage limitation at 1 kV/µs (line-earth) static (Additional descriptions)≤ 650 V
Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system (Additional descriptions)typ. 2.2 MHz

Product Description

PT plug-in protection with 2-channel protection circuit for high signal voltages, optical fault indication. Rated voltage: 230 V AC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top