Service time: Monday to Friday 9:00-18:00
PT 2X1-VF-230AC-ST - PT 2X1-VF-230AC-ST 2921365 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

PT 2X1-VF-230AC-ST

PT 2X1-VF-230AC-ST 2921365 PHOENIX CONTACT Surge protection plug

$0.00USD
4879 in stock
Key Specifications
:C2
Note:2002
Type:Male
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C2
Note2002
TypeMale
Colorblack (RAL 9005)
Depth51.7 mm
Width17.5 mm
Height44.8 mm
Altitude≤ 2000 m (amsl)
Product typeSurge protection for MCR technology
Screw threadM3
Mounting typeon base element
Rated current6 A
Product familyPLUGTRAB PT
Open side panelNo
Article revision08
Horizontal pitch1 Div.
Housing materialPA 6.6
Response time tA≤ 100 ns
Connection methodScrew connection (in connection with the base element)
Tightening torque0.8 Nm
Nominal voltage UN230 V AC
Switching functionN/C contact
Dimensional drawing
Direction of actionLine-Line & Line-Earth Ground
Number of positions2
Resistance per path0 Ω
Capacity (Core-Core)typ. 1.5 pF
Degree of protectionIP20
Residual current IPE≤ 2 µA (at UN)
Capacity (Core-Earth)typ. 3 pF
Complete module depth65.5 mm
Complete module width17.7 mm
Complete module height90 mm
IEC test classificationC1
Standards/specificationsEN 61643-21
Max. required back-up fuse6 A (gL/gG)
Conductor cross section AWG24 ... 12
Conductor cross section rigid0.2 mm² ... 4 mm²
Max. energy absorption (2 ms)150 J
Maximum continuous voltage UC250 V AC
Surge protection fault messagenone
Ambient temperature (operation)-40 °C ... 80 °C
Impulse durability (line-earth)C2 - 4 kV / 2 kA
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Operating effective current ICat UC≤ 2 µA
Max. discharge current Imax(8/20) µs8 kA
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs3 kA
Voltage protection level Up(line-line)≤ 2.5 kV (C2 - 4 kV / 2 kA)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Voltage protection level Up(line-earth)≤ 1.1 kV (C1 - 500 A)
Residual voltage at In(conductor-ground)≤ 1 kV
Pulse discharge current Iimp(10/350) µs500 A
Total discharge current Itotal(8/20) µs8 kA
Residual voltage at In(conductor-conductor)≤ 2 kV
Total discharge current Itotal(10/350) µs1 kA
Residual voltage with Ian (10/1000) µs (line-line)≤ 1.4 kV
Nominal pulse current Ian (10/1000) µs (line-earth)100 A
Residual voltage with Ian (10/1000) µs (line-earth)≤ 700 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 1.4 kV

Product Description

Plug-in protection with leakage current-proof protection circuit for two signals without earth potential. Series circuit consisting of varistor and a gas-filled surge arrester between the signal and g
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top