| Parameter | Value |
|---|---|
| GTIN | 4017918574987 |
| Orderkey | 2817958 |
| (General) | 6 kV (12 Ω) |
| Catalog page | Page 72 (C-4-2017) |
| Packing unit | 10 pc |
| Country of origin | DE (Germany) |
| (Connection data) | IEC 61643-11 2011 |
| Custom tariff number | 85363090 |
| (Ambient conditions) | (L+/L-) - PE |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Type (Ambient conditions) | DIN rail module, two-section, divisible |
| Color (Ambient conditions) | jet black RAL 9005 |
| Depth (Key Commercial Data) | 65.5 mm (incl. DIN rail 7.5 mm) |
| Width (Key Commercial Data) | 17.7 mm |
| EN type (Ambient conditions) | T3 |
| Height (Key Commercial Data) | 90 mm |
| Nominal voltage UN (General) | 48 V DC |
| Combination wave UOC (General) | 1 kV (2 Ω) |
| Residual current IPE (General) | ≤ 10 µA |
| Rated load current IL (General) | 26 A (30 °C) |
| Response time tA(L-N) (General) | ≤ 1 ns |
| Response time tA(L-PE) (General) | ≤ 1 ns |
| Degree of protection (Dimensions) | IP20 |
| Screw thread (Protective circuit) | M3 |
| Mounting type (Ambient conditions) | DIN rail: 35 mm |
| Number of ports (Ambient conditions) | One |
| Weight per Piece (excluding packing) | 63.460 g |
| Housing material (Ambient conditions) | PA 6.6 |
| Stripping length (Protective circuit) | 8 mm |
| Voltage protection level Up (General) | ≤ 120 V |
| Connection method (Protective circuit) | Screw connection |
| Horizontal pitch (Key Commercial Data) | 1 Div. |
| Operating current (Protective circuit) | 5 mA DC ... 15 mA (open collector) |
| Operating voltage (Protective circuit) | 7 V DC ... 70 V DC (open collector) |
| Tightening torque (Protective circuit) | 0.8 Nm |
| Maximum continuous voltage UC (General) | 60 V DC |
| Mode of protection (Ambient conditions) | L-N |
| Switching function (Protective circuit) | N/C contact |
| Degree of pollution (Ambient conditions) | 2 |
| Screw thread (Indicator/remote signaling) | M3 |
| Standards/specifications (Connection data) | EN 61643-11 2012 |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 80 °C |
| Short-circuit current rating ISCCR (General) | 200 A (without backup fuse for Uc) |
| Max. backup fuse with branch wiring (General) | 50 A (gG) |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Stripping length (Indicator/remote signaling) | 8 mm |
| Connection method (Indicator/remote signaling) | Screw connection |
| Tightening torque (Indicator/remote signaling) | 0.8 Nm |
| Conductor cross section AWG (Protective circuit) | 24 ... 12 |
| Maximum backup fuse for through wiring (General) | 25 A (gG) |
| Nominal discharge current In(8/20) µs (General) | 500 A |
| Conductor cross section solid (Protective circuit) | 0.2 mm² ... 4 mm² |
| Surge protection fault message (Ambient conditions) | Optical, remote indicator contact |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Conductor cross section flexible (Protective circuit) | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG (Indicator/remote signaling) | 24 ... 12 |
| Conductor cross section solid (Indicator/remote signaling) | 0.2 mm² ... 4 mm² |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Conductor cross section flexible (Indicator/remote signaling) | 0.2 mm² ... 2.5 mm² |
Technical specifications and performance data