Service time: Monday to Friday 9:00-18:00
PLT-T3-230-FM - PLT-T3-230-FM 2906491 PHOENIX CONTACT Type 3 surge protection device
In Stock Hot Product

PLT-T3-230-FM

PLT-T3-230-FM 2906491 PHOENIX CONTACT Type 3 surge protection device

$0.00USD
4404 in stock
Key Specifications
GTIN:4055626082066
Note:Made to Order (non-returnable)
Orderkey:2906491
(General):1455 V AC (200 ms / safe failure mode)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626082066
NoteMade to Order (non-returnable)
Orderkey2906491
(General)1455 V AC (200 ms / safe failure mode)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)N-G
Custom tariff number85363090
(Ambient conditions)N-PE
(Protective circuit)1 A DC (30 V DC)
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
SPD Type (Connection data)4CA
Depth (Key Commercial Data)65.5 mm
Width (Key Commercial Data)17.7 mm
EN type (Ambient conditions)T3
Height (Key Commercial Data)90 mm
Nominal voltage UN (General)230 V AC (TN-S)
Combination wave UOC (General)6 kV
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 5 µA
Rated load current IL (General)16 A AC (at 63 °C)
Response time tA(L-N) (General)≤ 25 ns
Response time tA(L-PE) (General)≤ 100 ns
Response time tA(N-PE) (General)≤ 100 ns
Degree of protection (Dimensions)IP20
Screw thread (Protective circuit)M3
TOV behavior at UT(L-N) (General)440 V AC (5 s / withstand mode)
Mounting type (Ambient conditions)DIN rail: 35 mm
TOV behavior at UT(L-PE) (General)440 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE) (General)1200 V AC (200 ms / safe failure mode)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)L-N
Number of ports (Ambient conditions)One
Weight per Piece (excluding packing)78.000 g
Housing material (Ambient conditions)PA 6.6
Reference test voltage UREF (General)255 V AC
Stripping length (Protective circuit)8 mm
Tightening torque (UL specifications)5 lbf-in. ... 7 lbf-in.
Connection method (Protective circuit)Screw connection
Horizontal pitch (Key Commercial Data)1 Div.
Operating current (Protective circuit)3 A AC
Operating voltage (Protective circuit)250 V AC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Standby power consumption PC (General)≤ 350 mVA
Tightening torque (Protective circuit)0.8 Nm
Maximum continuous voltage UC (General)255 V AC
Mode of protection (Ambient conditions)L-N
Switching function (Protective circuit)N/C contact
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)2
Screw thread (Indicator/remote signaling)M3
Voltage protection level Up(L-N) (General)≤ 1.25 kV
Power distribution system (Connection data)Single phase
Voltage protection level Up(L-PE) (General)≤ 1.4 kV
Voltage protection level Up(N-PE) (General)≤ 1.4 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TT
Short-circuit current rating ISCCR (General)1.5 kA AC
Max. backup fuse with branch wiring (General)16 A (B)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Standards/specifications (UL connection data)EN 61643-11 2012
Stripping length (Indicator/remote signaling)8 mm
Connection method (Indicator/remote signaling)Screw connection
Nominal discharge current In (Connection data)3 kA
Tightening torque (Indicator/remote signaling)0.8 Nm
Conductor cross section AWG (UL specifications)14 ... 12
Conductor cross section AWG (Protective circuit)24 ... 12
Maximum backup fuse for through wiring (General)16 A (B)
Nominal discharge current In(8/20) µs (General)3 kA
Tightening torque (UL indicator/remote signaling)5 lbf-in. ... 7 lbf-in.
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Measured limiting voltage MLV (L-G) (Connection data)1200 V
Measured limiting voltage MLV (L-N) (Connection data)1500 V
Measured limiting voltage MLV (N-G) (Connection data)1200 V
Conductor cross section AWG (Indicator/remote signaling)24 ... 12
Conductor cross section solid (Indicator/remote signaling)0.2 mm² ... 4 mm²
Conductor cross section AWG (UL indicator/remote signaling)14 ... 12
Flammability rating according to UL 94 (Ambient conditions)V-0
Maximum continuous operating voltage MCOV (Connection data)255 V AC
Conductor cross section flexible (Indicator/remote signaling)0.2 mm² ... 2.5 mm²

Product Description

Plug-in device protection, according to type 3/class III, for single-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with remote indication contact.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top