Service time: Monday to Friday 9:00-18:00
PLT-SEC-T3-120-FM-PT - PLT-SEC-T3-120-FM-PT 2907927 PHOENIX CONTACT Type 3 surge protection device
In Stock Hot Product

PLT-SEC-T3-120-FM-PT

PLT-SEC-T3-120-FM-PT 2907927 PHOENIX CONTACT Type 3 surge protection device

$0.00USD
4448 in stock
Key Specifications
GTIN:4055626257631
Orderkey:2907927
(General):1332 V AC (200 ms / safe failure mode)
Packing unit:5 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626257631
Orderkey2907927
(General)1332 V AC (200 ms / safe failure mode)
Packing unit5 pc
(Dimensions)≤ 6000 m (operating voltage remote contact ≤ 150 V)
Country of originDE (Germany)
(Connection data)EN 61643-11 2012
Custom tariff number85363030
(Ambient conditions)PA 6.6-FR
(Protective circuit)(DC+/DC-) - PE
Altitude (Dimensions)≤ 2000 m (operating voltage remote contact ≤ 250 V)
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)light gray RAL 7035
Depth (Key Commercial Data)74.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.7 mm
(Additional technical data)0.5 A DC (75 V DC)
EN type (Ambient conditions)T2 / T3
Height (Key Commercial Data)101 mm
Nominal voltage UN (General)120 V AC (TN-S)
Combination wave UOC (General)6 kV
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 5 µA
Shock (operation) (Dimensions)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)26 A (at 30 °C)
Response time tA(L-N) (General)≤ 25 ns
Response time tA(L-PE) (General)≤ 100 ns
Response time tA(N-PE) (General)≤ 100 ns
Degree of protection (Dimensions)IP20
TOV behavior at UT(L-N) (General)240 V AC (5 s / withstand mode)
Mounting type (Ambient conditions)DIN rail: 35 mm
TOV behavior at UT(L-PE) (General)240 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE) (General)1200 V AC (200 ms / safe failure mode)
Vibration (operation) (Dimensions)5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
Number of ports (Ambient conditions)One
Weight per Piece (excluding packing)77.160 g
Housing material (Ambient conditions)PA 6.6-FR 20% GF
Reference test voltage UREF (General)132 V AC
Horizontal pitch (Key Commercial Data)1 Div.
Standby power consumption PC (General)≤ 10.6 mVA (at UREF)
Maximum continuous voltage UC (General)150 V AC
Mode of protection (Ambient conditions)L-N
Mode of protection (Protective circuit)(DC+) - (DC-)
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)2
Standards/specifications (Connection data)IEC 61643-11 2011
Voltage protection level Up(L-N) (General)≤ 0.75 kV (at UOC)
Voltage protection level Up(L-PE) (General)≤ 0.85 kV
Voltage protection level Up(N-PE) (General)≤ 0.85 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TT
Short-circuit current rating ISCCR (General)10 kA AC
Stripping length (Additional technical data)10 mm
Connection method (Additional technical data)Push-in connection
Max. backup fuse with branch wiring (General)32 A (gG / B / C)
Operating current (Additional technical data)0.5 A AC
Operating voltage (Additional technical data)250 V AC
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)10 mm
Connection method (Indicator/remote signaling)Push-in connection
Switching function (Additional technical data)PDT contact
Max. discharge current Imax(8/20) µs (General)10 kA
Maximum backup fuse for through wiring (General)25 A (gG / B / C)
Nominal discharge current In(8/20) µs (General)5 kA
Maximum continuous voltage UC (Protective circuit)150 V DC
Impulse durability (line-line) (Protective circuit)D1 - 500 A
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Impulse durability (line-earth) (Protective circuit)D1 - 500 A
Conductor cross section AWG (Additional technical data)30 ... 12
Short-circuit current rating ISCCR (Protective circuit)0.25 kA DC (without additional backup fuse)
Conductor cross section AWG (Indicator/remote signaling)24 ... 12
Conductor cross section solid (Additional technical data)0.2 mm² ... 2.5 mm²
Conductor cross section solid (Indicator/remote signaling)0.2 mm² ... 4 mm²
Flammability rating according to UL 94 (Ambient conditions)V-0
Conductor cross section flexible (Additional technical data)0.2 mm² ... 2.5 mm²
Conductor cross section flexible (Indicator/remote signaling)0.2 mm² ... 2.5 mm²
Pulse discharge current Iimp(10/350) µs (line-line) (Protective circuit)0.5 kA
Pulse discharge current Iimp(10/350) µs (line-earth) (Protective circuit)0.5 kA
IEC test classification (in accordance with IEC 61643-21) (Protective circuit)D1

Product Description

Type 2/3 surge protection, consisting of plug-in protection and base element, with integrated status indicator and remote indication for single-phase power supply networks. Rated Voltage: 120VAC/DC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top