| Parameter | Value |
|---|---|
| GTIN | 4046356073455 |
| Orderkey | 2882381 |
| Catalog page | Page 74 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| EN type (General) | T3 |
| Custom tariff number | 85363010 |
| Type (Ambient conditions) | Attachment plug |
| Color (Ambient conditions) | jet black RAL 9005 |
| Depth (Key Commercial Data) | 78 mm |
| Width (Key Commercial Data) | 63 mm |
| Height (Key Commercial Data) | 103 mm |
| Nominal voltage UN (General) | 230 V AC |
| Response time (L-N) (General) | ≤ 25 ns |
| Combination wave UOC (General) | 4 kV |
| Nominal frequency fN (General) | 50 Hz (60 Hz) |
| Residual current IPE (General) | ≤ 5 µA |
| Response time (L-PE) (General) | ≤ 100 ns |
| Response time (N-PE) (General) | ≤ 100 ns |
| Rated load current IL (General) | 16 A (30 °C) |
| Mounting type (Ambient conditions) | Plugging into the mains socket |
| Max. required back-up fuse (General) | 16 A (gG / B / C) |
| Weight per Piece (excluding packing) | 194.000 g |
| Housing material (Ambient conditions) | PA 6 |
| Standby power consumption PC (General) | ≤ 1 VA |
| Energy absorption symmetrical (General) | 140 J (L-N) |
| Arrester rated voltage UC(L-N) (General) | 275 V AC |
| Direction of action (Ambient conditions) | L/N-PE & Signal Line-Earth Ground |
| Enery absorption, asymmetrical (General) | 220 J (L(N)-PE) |
| Surge protection fault message (General) | optical |
| Arrester rated voltage UC(L-PE) (General) | 360 V AC |
| Arrester rated voltage UC(N-PE) (General) | 360 V AC |
| Connection method (Power supply, general) | Via protective contact plug |
| Voltage protection level Up(L-N) (General) | ≤ 1.2 kV |
| Voltage protection level Up(L-PE) (General) | ≤ 1.5 kV |
| Voltage protection level Up(N-PE) (General) | ≤ 1.5 kV |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 75 °C |
| (Connection (protective circuit, power supply)) | D1 - 500 A |
| For country-specific use in (Ambient conditions) | D |
| Nominal discharge current In(8/20) µs (General) | 3 kA (> 5x) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 75 °C |
| Connection method (Protective circuit, power supply) | Grounding plug/socket |
| Connection method IN (Protective circuit, power supply) | Grounding plug |
| Connection method OUT (Protective circuit, power supply) | Grounding socket |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| (Connection, equipotential bonding, information technology) | D1 |
| Rated current (Connection (protective circuit, power supply)) | 150 mA (25 °C) |
| Connection method (Protective circuit, information technology) | RJ12-/TAE 6 |
| Connection method IN (Protective circuit, information technology) | RJ12 female connector |
| Connection method OUT (Protective circuit, information technology) | TAE 6 socket |
| Capacity (line-line) (Connection (protective circuit, power supply)) | typ. 1 nF |
| Residual current IPE (Connection (protective circuit, power supply)) | ≤ 2 µA |
| Capacity (line-earth) (Connection (protective circuit, power supply)) | typ. 5 pF |
| Arrester rated voltage UC (Connection (protective circuit, power supply)) | 200 V DC |
| Insulation resistance Riso (Connection (protective circuit, power supply)) | ≥ 1 MΩ |
| Response time tA(line-line) (Connection (protective circuit, power supply)) | ≤ 25 ns |
| Pulse reset time (line-line) (Connection (protective circuit, power supply)) | ≤ 15 ms |
| Response time tA(line-earth) (Connection (protective circuit, power supply)) | ≤ 100 ns |
| Impulse durability (line-line) (Connection (protective circuit, power supply)) | C2 - 2 kV / 1 kA |
| Impulse durability (line-earth) (Connection (protective circuit, power supply)) | C2 - 4 kV/2 kA |
| Residual voltage at In(line-line) (Connection (protective circuit, power supply)) | ≤ 500 V |
| Residual voltage at In(line-earth) (Connection (protective circuit, power supply)) | ≤ 30 V |
| IEC test classification (Connection, equipotential bonding, information technology) | C1 |
| Operating effective current ICat UC (Connection (protective circuit, power supply)) | ≤ 150 µA |
| Max. discharge current Imax(8/20) µs (Connection (protective circuit, power supply)) | 2.5 kA |
| Voltage protection level Up(line-line) (Connection (protective circuit, power supply)) | ≤ 460 V (C2 - 1 kA) |
| Voltage protection level Up(line-earth) (Connection (protective circuit, power supply)) | ≤ 900 V (C2 - 2 kA) |
| Alternating current carrying capacity (line-line) (Connection (protective circuit, power supply)) | 250 mA - 1 s |
| Output voltage limitation at 1 kV/µs (wire-wire) (Connection (protective circuit, power supply)) | ≤ 360 V |
| Alternating current carrying capacity (line-earth) (Connection (protective circuit, power supply)) | 10 A - 1 s |
| Nominal discharge current In(8/20) µs (line-line) (Connection (protective circuit, power supply)) | 1 kA |
| Cut-off frequency fg (3 dB), sym. in 100 Ohm system (Connection (protective circuit, power supply)) | typ. 4 MHz |
| Cut-off frequency fg (3 dB), sym. in 150 Ohm system (Connection (protective circuit, power supply)) | typ. 3 MHz |
| Cut-off frequency fg (3 dB), sym. in 600 Ohm system (Connection (protective circuit, power supply)) | typ. 700 kHz |
| Nominal discharge current In(8/20) µs (line-earth) (Connection (protective circuit, power supply)) | 2.5 kA |
| Residual voltage with Ian (10/1000) µs (line-line) (Connection (protective circuit, power supply)) | ≤ 35 V |
| Residual voltage with Ian (10/1000) µs (line-earth) (Connection (protective circuit, power supply)) | ≤ 35 V |
Technical specifications and performance data